Woodward GCP-10 Series Application Note
Woodward GCP-10 Series Application Note

Woodward GCP-10 Series Application Note

Replacement of gcp-10 series with easygen-1500

Advertisement

Quick Links

37338
Replacement of GCP-10 Series with easYgen-1500
Application Note
Application Note
easYgen-1500 Software Version 2.0xxx
Manual 37338

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GCP-10 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Woodward GCP-10 Series

  • Page 1 37338 Replacement of GCP-10 Series with easYgen-1500 Application Note Application Note easYgen-1500 Software Version 2.0xxx Manual 37338...
  • Page 2 Provides other helpful information that does not fall under the warning or caution categories. Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward is believed to be correct and reliable. However, Woodward assumes no responsibility unless otherwise expressly undertaken.
  • Page 3: Table Of Contents

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Revision History Rev. Date Editor Changes NEW 05-06-22 Release Content 1. I .......................4 HAPTER NTRODUCTION 2. R GCP-11 -1500 ............5 HAPTER EPLACEMENT WITH EAS Technical Data ............................5 Functional Overview..........................6 Terminal Overview ..........................6...
  • Page 4: Chapter 1. Introduction

    5448-880 GCP-1210B/X 5448-881 GCP-1210B 8440-1015 GCP-1240B It is possible to configure both units by PC with the Woodward software tool LeoPC1 V3.1.1 The required communication cable is offered separately under the P/N: 5417-557, COMMUNICATION DEVICE-DPC. Page 4/13 © Woodward...
  • Page 5: Chapter 2. Replacement Gcp-11 With Easygen-1500

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Chapter 2. Replacement GCP-11 with easYgen-1500 Technical Data ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ GCP-11 easYgen-1500 Voltage measurement 100 to 115 VAC or 69/120 VAC and 380 to 440 VAC 277/480 VAC Current measurement...
  • Page 6: Functional Overview

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Functional Overview ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ Both units have following functions and features: • Start-stop logic for diesel or gas engines • Generator voltage, frequency, and over current protection • Generator breaker control •...
  • Page 7: Wiring Overview

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Wiring Overview ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ crank Fuel solenoid Remote start Battery 0 VDC Battery 12/24V + GCP-11 3 28 61 62 90 92 37 38 41 22 23 24 55 56...
  • Page 8: Parameter Assignment

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Parameter Assignment ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ The easYgen requires the following settings, in order to operate similarly to the GCP-11. For details please refer to the Installation Manual (refer to Introduction on page 4 for more info about the manu- als).
  • Page 9: Chapter 3. Replacement Gcp-12 With Easygen-1500

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Chapter 3. Replacement GCP-12 with easYgen-1500 Technical Data ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ GCP-12 easYgen-1500 Voltage measurement 100 to 115 VAC or 69/120 VAC and 380 to 440 VAC 277/480 VAC Current measurement...
  • Page 10: Functional Overview

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Functional Overview ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ Both units have following functions and features: • Start-stop logic for Diesel or gas engines • Generator voltage and frequency monitoring • Mains voltage and frequency monitoring, AMF mode •...
  • Page 11: Wiring Overview

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Wiring Overview ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ crank Fuel solenoid Remote start Battery 0 VDC Battery 12/24V + GCP-12 3 28 61 62 90 92 41 42 23 24 0 Easy Gen 48 52 53 51 54 9 10...
  • Page 12: Parameter Assignment

    Manual 37338 Replacement of GCP-10 Series with easYgen-1500 - Application Note Parameter Assignment ≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡≡ The easYgen requires the following settings, in order to operate similarly to the GCP-12. For details please refer to the Installation Manual (refer to Introduction on page 4 for more info about the manu- als).
  • Page 13 Phone +49 (0) 711 789 54-0 • Fax +49 (0) 711 789 54-100 sales-stuttgart@woodward.com Homepage http://www.woodward.com/power Woodward has company-owned plants, subsidiaries, and branches, as well as authorized distributors and other authorized service and sales facilities throughout the world. Complete address/phone/fax/e-mail information for all locations is available on our website (www.woodward.com).

Table of Contents