Installation - Graco Fire-Ball 300 D Series Instructions Manual

Table of Contents

Advertisement

Installation

Grounding
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Pump: Use a ground wire and clamp as shown in F
1.
Fluid hoses: Use only electrically conductive hoses.
Air compressor: Follow manufacturer's recommenda-
tions.
Fluid supply container: Follow the local code.
B
A
K
F
. 2: Typical Installation
IG
Key:
A
Fluid dispense line
B
Pump ground wire (required)
C
Air regulator with gauge
D
Main air supply line
E
Air line filter
308883S
To maintain grounding continuity when flushing or
relieving pressure: hold metal part of the spray
gun/dispense valve firmly to the side of a grounded
metal pail, then trigger the gun/valve.
To ground the pump: remove the ground screw (Z)
and insert through the eye of the ring terminal at end of
the ground wire (Y). Fasten the ground screw back onto
the pump and tighten securely. Connect the other end of
the ground wire to a true earth ground. See Fig. To
order a ground wire clamp, order Part. No. 222011.
.
IG
F
. 1
IG
G
J
C
E
F
H
1/2 in.
F
Air line lubricator
G
Pump runaway valve
H
Follower plate
J
Bleed-type master air valve (required)
K
Fluid drain valve
Z
Y
Recommended air line
configuration to reduce
moisture in pump
D
J
Installation
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fire-ball 239877Fire-ball 239887Fire-ball 239888Fire-ball 300239877239887 ... Show all

Table of Contents