Depending on the actuator, button inputs are taught
differently:
Actuator
Button behavior
Switch actuator,
Taught buttons behave like
Dimming actuator
toggle switches
Depending on whether teach
mode on the actuator was trig-
gered with the ▲- or ▼- button,
Blind actuator
the button to be taught is taught
as "Open" or "Close", not as a
toggle button.
If a button that was taught for an actuator is
taught for the same actuator again, the old
assignment is overwritten.
7.2 Clearing the assignment of button
inputs to actuator channels
Clearing the assignment of a button input and actuator
(channel)
• Press the programming button of the actuator
(channel) that you want to clear the assignment
for until the respective channel LED switches
36
from slow flashing to quickly flashing (after ap-
prox. 6 seconds).
• Release the button. The module is now in delete
mode.
• Now, press a button on the button input of a mo-
dule for which you want to clear the assignment.
The channel LED on the actuator goes dark and
the assignment is deleted, the actuator (channel)
is no longer actuated on this switch input.
• Test the setting by actuating a button on the de-
leted button input, the actuator (channel) should
not react.
All teach procedures can be aborted by briefly
actuating the programming button.
8

Maintenance and cleaning

This product is maintenance-free. Repairs are only to
be done by trained professionals.