Permitted wire cross-sections.
Rigid wire [mm
]
2
0.14 – 2.50
7

Allocation of button inputs

The 12 button inputs of the HMW-IO-12-Sw7-DR can
be assigned to actuator channels of other(!) actuators
that have channel buttons on the device without the
HomeMatic center.
Since this device has no programming button
for the output channels, the output channels
can only be assigned via the HomeMatic Center. The
device is completely unprogrammed in delivery status.
7.1 Teaching button inputs to
actuator channels
Please read this section completely before star-
ting with any configuring!
34
Flexible wire with end
sleeve [mm
]
2
0.14 – 1.5
The button inputs are not assigned to any
actuator channels in factory status (not the
actuator channels of the device on which they are
located either).
Assignment of button inputs to actuator channels
• Press the programming button of the actuator
(channel) to be assigned on the module until
the channel LED flashes slowly (after approx. 3
seconds). The module is now in teach mode.
• Now, actuate a button on the button input (on the
same module or any other module on the bus)
that you want to assign to the actuator (channel).
• The actuator (channel) is now assigned with this
switch input and the channel LED goes dark on
the actuator.
• Test the assignment by pressing the respective
button. The actuator (channel) should react ac-
cording to the configuration of the button input.
• If you want to assign another button input to the
actuator (channel), repeat this procedure.