The following instructions describe how to install the controller into a Hitachi Universal V2 rack. For information about
installing the controller in a third-party rack, see the documentation for that rack.
WARNINGDue to the heavy weight of the controller, use a mechanical lift or at least three people to lift and mount the
controller in the rack.
Before you begin
• Make sure you have a 19-inch rack that is secure and cannot fall over.
• Make sure the rack has one or more PDUs installed.
• Verify that all power cables are removed from the AC power receptacles on the rear of the controller.
• Install the rack stabilizers before mounting the storage system in the rack.
Procedure
1. Loosen the four adjustment screws, if needed, so that the rail halves can be adjusted freely to fit between the front
and rear vertical rack posts.