Warning
Never operate the monitor when the cover is removed.
Remove the monitor cover and battery only in area known as non-hazardous.
Use only mPower's lithium battery part number12.01.09.0001.
This instrument has not been tested in an explosive gas/air atmosphere
having an oxygen concentration greater than 21%.
Substitution of components will impair suitability for intrinsic safety and void
warranty.
It is recommended to bump test with a known concentration gas to confirm
the instrument is functioning properly before use.
Before use, ensure that the ESD film on the display is not damaged or peeling.
Avertissement:
N'utilisez jamais le moniteur lorsque le couvercle est enlevé.
Retirer le couvercle du moniteur et la batterie uniquement dans une zone
connue comme non dangereuse.
Utilisez uniquement le numéro de pièce de la batterie au lithium
mPower12.01.09.0001.
Cet instrument n'a pas été testé dans une atmosphère explosive gaz / air
ayant une concentration en oxygène supérieure à 21%.
La substitution de composants compromettra l'aptitude à la sécurité
intrinsèque et annulera la garantie.
Il est recommandé de tester avec un gaz de concentration connu pour confirme
r que l'instrument fonctionne correctement avant de l'utiliser.
Avant de l'utiliser, assurez-vous que le film ESD sur l'écran n'est pas
endommagé ou épluché.
Read Before Operating
This manual must be carefully read by all individuals
who have or will have the responsibility of using,
maintaining or servicing this product. The product
will perform as designed only if it is used, maintained
and serviced in accordance with the manufacturer's
instructions.
Caution
Change battery only in area known to be
non-hazardous.
Use
12.01.09.0001.
Attention:
Changez la batterie uniquement dans une
zone connue pour être non dangereuse.
Utiliser uniquement la batterie mPower
PN: PN: 12.01.09.0001.
v1.0
Two key operation, four sensor sockets, one big LCD,
eight alarm LEDs, one buzzer, two vibration alarms.
LED Alarm
Buzzer
Left Key
(Confirm
/Number
Increase)
LCD
2

WARNINGS

only
mPower's

User Interface

Gas Inlet
Charge/Comm Port
battery
PN:
1
Sensor
Right Key
(Power/
Cursor Moving)
LED Alarm
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POLI MP400 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for mPower Electronics POLI MP400 Series

  • Page 1 12.01.09.0001. Attention: ⚫ Changez la batterie uniquement dans une mPower Electronics Inc. 3046 Scott Blvd. Santa Clara, CA 95054 zone connue pour être non dangereuse. Phone: +1(408)320-1266 ⚫ Utiliser uniquement la batterie mPower Fax: +1(669)342-7077 PN: PN: 12.01.09.0001.
  • Page 2 Turning the Unit On Normal Mode Press and hold the Right Key for 3 seconds, until After warm up finished, unit enters normal reading buzzer beeps, red LED on, unit is powered on. After mode, start monitoring gas concentration and the warm up and self-test sequence, unit enters normal reading value will be displayed on the LCD screen.
  • Page 3 Bump Test Fresh Air Calibration Bump test is to check if the sensors and alarms are Fresh air calibration is to get the baseline for sensor, it still working properly. is done in normal fresh air. ⚫ ⚫ To enter bump test: To enter fresh air calibration: Config mode →...

Table of Contents