Download Print this page

Assa Abloy Corbin Russwin IN100 Installation Instructions Manual page 9

Mortise lockset
Hide thumbs Also See for Corbin Russwin IN100:

Advertisement

IN100 Mortise Lock
5.
Install Lock Body in Door:
a. Feed wires through 1-5/16" diameter hole on INSIDE of door while installing lock body (Fig. 5a).
b. Pull wires through hole while inserting lock body. DO NOT push wires back into cylinder hole (Fig. 5b).
Important: Door must remain open during installation. Use door stop.
c. Install, but do not tighten two #12 x 1" combination screws through lock body (Fig. 5a).
Fig. 5a
6.
Install Cylinder:
a. Slide cylinder through collar. Thread cylinder into lock body
(Fig. 6a).
Note: Make sure cylinder is oriented correctly (Fig. 6a1).
b. Tighten cylinder clamp using 7/64" allen wrench (Fig. 6b).
c. Turn the key to make sure that lock functions correctly
(latch, deadbolt, and key).
Fig. 6a
Copyright © 2016 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
5) Installation Instructions (Continued)
Outside Face of Door
(2) #12 x 1"
Do not tighten
Position cylinder so that the logo is right-
side up.
Correct
Fig. 6a1
9
Inside Face of Door
Incorrect
Fig. 6b
DPS
From Lock Body
Fig. 5b
7/64" Allen Wrench

Advertisement

loading