Accelnet & Stepnet Plus Panels STO Manual
7.4 Safety Related Parameters
Servo, 1-Axis: BEL, BPL
SIL
Table 10
PFH
PFD
Servo, 2-Axis: BE2, BP2
SIL
Table 11
PFH
PFD
Stepper, 1-Axis: TEL
SIL
Table 12
PFH
PFD
Stepper, 2-Axis: TE2, TP2
SIL
Table 13
PFH
PFD
Page 17 of 34
IEC 61508: 2010
3
HFT
-9
3.3 x 10
SFF
-4
2.9 x 10
PTI
IEC 61508: 2010
3
HFT
-9
3.3 x 10
SFF
-4
2.9 x 10
PTI
IEC 61508: 2010
3
HFT
-9
3.3 x 10
SFF
-4
2.9 x 10
PTI
IEC 61508: 2010
3
HFT
-9
3.3 x 10
SFF
-4
2.9 x 10
PTI
ISO 13849-1: 2006
2
PL
d
<60%
CCF
80
20 yrs
DC
69%
ISO 13849-1: 2006
2
PL
d
<60%
CCF
80
20 yrs
DC
73%
ISO 13849-1: 2006
2
PL
d
<60%
CCF
80
20 yrs
DC
71%
ISO 13849-1: 2006
2
PL
d
<60%
CCF
80
20 yrs
DC
73%
Category
3
MTTF
100 yrs
D
Category
3
MTTF
100 yrs
D
Category
3
MTTF
100 yrs
D
Category
3
MTTF
100 yrs
D
16-01338 Rev 00
Copley Controls
Need help?
Do you have a question about the Accelnet and is the answer not in the manual?
Questions and answers