  • Page 1 Installer manual SW24.D 24 Vdc control panel for swing gates...
  • Page 2: Table Of Contents

    SW24.D Contents: Page 1 - Product features .......................................... 1 2 - System type ..........................................1 3 - Description of the terminal blocks ....................................2 4 - Connecting accessories ......................................4 5 - Control panel programming ......................................6 6 - DIP-switch functions ......................................... 10 7 - LED functions ..........................................
  • Page 3: Product Features

    SW24.D 1 - Product features Control panel for 24 Vdc swing gates with a rated power of 80 + 80W, equipped with an encoder interface to detect obstacles and control the speed, and an integrated 433 MHz receiver. The control panel: - can customize the slow-down distance and speed for both opening and closing - has an obstacle detection system - has LEDs input diagnostics and programming...
  • Page 4: Description Of The Terminal Blocks

    SW24.D 3 - Description of the terminal blocks PROGRAM. MENU' F2 (5X20) F3.15 A F1 (ATO) 15 A DIP2 SW24.D 51 52 61 62 21 22 25 26 12 19 14 1 0 10 11 +E -E 41 45 99 61 62 Terminal Description Rated data Terminal Description...
  • Page 5 SW24.D - 230 Vac - 120 Vac PROGRAM. MENU' F2 (5X20) F3.15 A F1 (ATO) ZBA6 SW24.D 21 22 25 26 12 19 14 1 0 10 11 +E -E 41 45 99 61 62 3.1 - Description of the output functions Accessories power supply: 24 Vdc output Functions according to the P08 parameter setting.
  • Page 6: Connecting Accessories

    SW24.D 3.2 - Description of the input functions Step by step (N.O.): Sequential control input, to control the full gate travel. Operating according to the setting for parameters P39 and P03: P39 = 0, P39 = 1 input 51 operating according to parameter P03. P39 = 2 input 51 only controls the opening.
  • Page 7 SW24.D 4.2 - Fotocellule e fotocellule in chiusura Contatto normalmente chiuso (a fotocellule non impegnate i LED 62 e 63 devono essere accesi), se non utilizzato fare un ponticello tra COM e 62, COM e 63, è necessario rispettare la polarità per l’alimentazione delle fotocellule: P06 = 1 P08 = OFF (FSW)
  • Page 8: Control Panel Programming

    SW24.D 4.5 - Stop push-button 99 61 62 5 - Control panel programming 5.1 - Preliminary operations All submenus are described in the table below. After powering the unit, the name of the control board written as Quick gate travel calibration. SW2.D, the firmware version FX.XX and 3 flashes with the word FLSH The calibration is fully self-performed and sets: appear in the display, then display then goes off.
  • Page 9 SW24.D Leaf 1 opening slow down. Step-bystep (4 steps logic) When button pressed: leaf 1 opening stop Cycle command Opens, Stops, Closes, position setting, if 51 is not pressed, the leaf Stops, Opens… learns as the opening stopping position the Step-bystep (2 steps logic) one obtained from the opening mechanical Cycle command Opens, Closes, Opens…...
  • Page 10 SW24.D M1 slowdown distance during opening M2 acceleration Knowing that 0 means full closing and 100 M2 acceleration ramp until normal speed is full opening, it shows where M1 switches (70) reached from normal speed to slow down speed on Accelerazione massima opening Accelerazione minima...
  • Page 11 SW24.D Dead-man operation Remote control management display ex. Dead-man not active Remote control button programming on Emergency dead-man: 1st channel (step-by-step or open, see - In regular operating conditions, standard P18) operation - If safaties are engaged, dead-man opera- Waiting the code (press the remote control oooo tion only on input 51 and 52 as per parameter button), the receiver is empty...
  • Page 12: Dip-Switch Functions

    Excessive absorption on the motor M2 power output Function Status Description Regulatory compliance The motors are equipped with en- Vimar SpA declares that this electronic device complies with EU direc- coders Motor with/with- Dip 2 tives 2014/53/UE, 2006/42/CE, 2014/30/EU, 2014/35/EU. The full text...