Advanced Parameter Setting For Remote Control - Acova FASSANE PREMIUM HORIZONTAL Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

5.3 Advanced parameter setting for remote control

WARNING!
Access to parameter setting is possible only when the remote control is off.
Some parameters on your remote control can be adjusted according to how you use it.
2
seconds
boost
mode
Parameter
number
boost
Back to
previous
mode
parameter.
No
Parameter
Description
0
Duration of
Adjustable from 15 to 120 minutes in 15 minute steps
Boost
operation
1
Window open
Value 0 (function disabled) or 1 (function enabled)
detection
2
Eco
Value 0 (eco temperature unlinked) or 1 (linked eco-
temperature
temperature setting: comfort T° minus 3.5°)
64
Press on P1P2 and
mode for 2 seconds
to enter.
Parameter
value
WARNING
It is essential to get
to the final "End" screen, to
confirm your parameter
Go to
changes.
the next
parameter.
Default
Setting
setting
60
Press the
1
Press the
1
Press the
No
Parameter
3
Pilot wire
4
Ambient
temperature
calibration
5
Selection of
temperature
boost
sensor
mode
6
None
7
Re-pairing
radio-
!
frequency
8
Default display Value 0 (time) or 1 (temperature setting)
9
Display
version
number and
+
-
or
key
reset
(unpairing).
+
-
or
key
End
Display
parameter
setting output
+
-
or
key
After no key has been pressed for one minute, the remote control will automatically
quit the advanced parameters and turn off.
40019308
05/2019
Description
Value 0 (pilot wire disabled) or 1 (pilot wire enabled)
Adjustable from -5.0°C to 5.0°C in 0.5°C steps
Value 1 (receiver unit) or 2 (remote control)
See chapter 5.4
Value 0 (unpaired command) or 1 (paired command)
Back to factory settings
Warning!
All your settings as well as the pairing, will be deleted.
If the remote control was paired before the reset, the
receiver unit will also be reset.
Quit the settings menu
Default
Setting
setting
1
Press the
+
or
-
key
0.0
+
-
Press the
or
key
1 or 2
+
-
Press the
or
key
rF0 or
Press on + or - key to*
rF1
re-pair an appliance
which was previously
paired but has lost the
link.
1
+
-
Press the
or
key
x.xx
Press on + key for 10
seconds to reset.
Short press on
mode or for
2 seconds on
.
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents