Functional Test
Disassembly and Assembly
Disassembly
Handle
25C1044 (TK)
Verify operation and reported malfunction, referring to the product
User's Guide for a description of the unit as well as information on its
operation, troubleshooting, and technical data.
! CAUTION !
Observe precautions when handling this static-sensitive device.
1. Remove the microphone cartridge from the UC2.
2. Use a pair of needlenosed pliers to remove the circuit board
retaining ring from inside the handle.
3. Push the bezel tab-snap in the handle behind the contact pcb to
remove the bezel and switch actuator.
4. Slide the circuit board out by pushing on the battery connectors.
Switch actuator
Tab
Figure 3. Bezel Removal
Shure UC2 Hand-Held UHF Transmitter
Bezel
Right side view of microphone
Tab
Contact pcb
Circuit board subassembly
9
Disassembly