Hanbay RC AS-1.05 Series User Manual page 9

Table of Contents

Advertisement

HANBAY Inc
Register name
TargetFromRS485Flag
Example: To have actuator number 11 taking the target
position from the "TargetPosition" register
This flag tells the actuator where the target position is coming from. If this value is 1 the actuator will take the value
from 4..20mA input as its target position. If this value is 0 the actuator will take the value from "TargetPosition"
register as its target position.
(Remember: all values sent to actuator are HEX)
Register name
InputRangeLow
Example: Set input range low to 4000 in actuator number
Register name
InputRangeHigh
Example: Set input range high to
For a detailed explanation of this two registers please see "TargetPosition" register description.
The value stored in "InputRangeLow" register must always be lower than the one stored in "InputRangeHigh".
If you try to write an illogical range, the actuator will answer with exception code 0x03 indicating that the new
value is not valid. (Remember: all values sent to actuator are HEX)
Register name
OutputRangeLow
Example: Set input range low to 4000 in actuator number
Register name
OutputRangeHigh
Example: Set input range high to
For a detailed explanation of this two registers please see "CurrentPosition" register description.
The value stored in "OutputRangeLow" register must always be lower than the one stored in
"OutputRangeHigh". If you try to write an illogical range, the actuator will answer with exception code 0x03
indicating that the new value is not valid. (Remember: all values sent to actuator are HEX)
Page 9 of 15
Rev.2018.1
Address
Max
Min
0x0003
2
0
Address
Max
Min
0x0004
64900
0
12
Address
Max
Min
0x0005
65000
100
in actuator number
65000
23
Address
Max
Min
0x0006
64900
0
12
Address
Max
Min
0x0007
65000
100
in actuator number
65000
23
Default
Actuator
address
N/A
0x0B
1 byte
Default
Actuator
0
address
0x0C
1 byte
Default
Actuator
address
10000
0x17
1 byte
Default
Actuator
address
0
0x0C
1 byte
Default
Actuator
address
10000
0x17
1 byte
User Manual RCx-xxxAS-1.05
Function
Register
Register
code
address
new value
0x06
0x0003
0x0000
1 byte
2 bytes
2 bytes
Function
Register
Register
code
address
new value
0x06
0x0004
0x0FA0
1 byte
2 bytes
2 bytes
Function
Register
Register
code
address
new value
0x06
0x0005
0xFDE8
1 byte
2 bytes
2 bytes
Function
Register
Register
code
address
New
value
0x06
0x0006
0x0FA0
1 byte
2 bytes
2 bytes
Function
Register
Register
code
address
new value
0x06
0x0007
0xFDE8
1 byte
2 bytes
2 bytes
www.hanbayinc.com
1 800 315 4461
hanbaysales@hanbayinc.com
CRC
0x----
2
bytes
CRC
0x----
2
bytes
CRC
0x----
2
bytes
CRC
0x----
2
bytes
CRC
0x----
2
bytes

Advertisement

Table of Contents
loading