Goodwe BH Series User Manual

Goodwe BH Series User Manual

Hybrid inverter
Hide thumbs Also See for BH Series:

Advertisement

PV Master APP
SEMS Portal APP
SEMS Portal website
LinkedIn
Company's
www.semsportal.com
offical website
BH SERIES USER MANUAL
JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD
No. 90 Zijin Rd., New District, Suzhou, 215011, China
HYBRID INVERTER
www.goodwe.com
340-00310-01
service@goodwe.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BH Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Goodwe BH Series

  • Page 1 PV Master APP SEMS Portal APP SEMS Portal website LinkedIn Company's www.semsportal.com offical website BH SERIES USER MANUAL JIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD No. 90 Zijin Rd., New District, Suzhou, 215011, China HYBRID INVERTER www.goodwe.com 340-00310-01 service@goodwe.com...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION 1.1 Operation Modes Introduction ..................01 1.2 Safety & Warning ........................ 02 1.3 Product Overview ......................04 INSTALLATION INSTRUCTIONS 2.1 Unacceptable Installations ....................05 2.2 Packing List ......................... 05 2.3 Mounting ..........................06 2.3.1 Select Mounting Location ..................06 2.3.2 Mounting ........................
  • Page 3: Introduction

    The BH series inverter of Jiangsu GoodWe Power Supply Technology Co., Ltd. (hereinafter GoodWe BH series bidirectional inverter is designed for both indoor and outdoor use, which could called as GoodWe) strictly complies with related safety rules for product design and testing.
  • Page 4: Product Overview

    The temperature of inverter surface might exceed 60℃ during working, so please make sure it is cooled down before touching it, and make sure the inverter is untouchable for children Do not open inverter cover or change any components without GoodWe's authorization, otherwise the warranty commitment for the inverter will be invalid.
  • Page 5: Installation Instructions

    Rule 6. Product label on inverter should be clearly visible after installation. On receiving the BH series inverter, please check to make sure all the components as below are not Rule 7. Leave enough space around inverter following the values.
  • Page 6: Mounting

    Step 3 Inverter cannot be installed near flammable, explosive or strong electro-magnetic equipment.[1] Ground cable must be connected to ground plate on grid side. 2.3.2 MOUNTING Inverter cannot be installed near flammable, explosive or strong electro-magnetic equipment.[1] Wi -Fi RE SE T SY ST EM BA CK -UP The inverter is suitable for mounting on concrete or other non-combustible surface only.
  • Page 7: On-Grid & Back-Up Connection

    Please following the steps as bellow strictly. Use improper wire may cause bad contact and high Inverter Model AC Breaker Specification impedance, which is dangerous to the system. GW3K-BH 50A/230V AC breaker • Use the right BAT plugs in the accessory box. GW3600-BH 50A/230V AC breaker GW5000-BH...
  • Page 8 In case of systems not connected to the batteries, the Back-Up function is strongly not advised to use. GoodWe shall not cover the An external AC breaker (≥32A) is needed for Back-Up connection to be isolate when necessary.
  • Page 9: Smart Meter & Ct Connection

    Accepted Loads As Below: House → Grid SMART METER BH series hybrid inverters are able to supply over load output at it's Back-Up. For details please Grid Reset refer to the technical parameters of BH series inverter (4.3 section). And the inverter has self-pro- tection derating at high ambient temperature.
  • Page 10: Dred / Remote Shutdown Connection

    Remote shutdown is only for Europe installations, in compliance with Europe safety require- REFGEN COM / DRMO Function ments. And Remote shutdown device is not provided by GoodWe. Screw Screw Cap Insulator Detailed operation is shown as below:...
  • Page 11: Earth Fault Alarm Connection

    Grid Power Meter 2.6 Earth Fault Alarm Connection BH series inverter complies with IEC 62109-2 13.9. Fault indicator LED on inverter cover will light ⑤ AC Breaker up and the system will email the fault information to customer. Inverter should be installed at eye level for convenient maintenance.
  • Page 12: Manual Operation

    System Connection Diagrams MAMUAL OPERATION Note: According to australian safety country, the neutral cable of on-grid side and back-up side must 3.1 Wi-Fi Configuration be connected together, otherwise back-up function will not work. This part shows configuration on web page. You can also complete the configuration with PV This diagram is an example for application that Neutral connects together with PE in Master App.
  • Page 13: Pv Master App

    Please download "PV Master Operation Instructions" from Overview Param www.goodwe.com 3.3 CEI Auto-Test Function PV auto-test function of CEI is integrated in PV Master App for Italy's safety country requirements. For detailed instruction of this function please refer to "PV Master Operation Instructions".
  • Page 14 QU curve Mode PU curve Mode 100% 100% INVERTER VOLTAGE, V INVERTER VOLTAGE, V LEGEND: LEGEND: var characteristic curve var characteristic curve QU curve Mode Example curve for a volt-watt response mode (Australia) Example curve for a volt-watt response mode (New Zealand) Function Default value (Australia) Default value (New Zealand)
  • Page 15: Others

    3.5 Startup/shutdown Procedure OTHERS 3.5.1 Startup Procedure 4.1 Troubleshootings Note: Before closing the AC breaker between the inverter and the grid, you need to use a multimeter to measure whether the AC voltage is within the allowable range. Checking Before Turn On AC Power step 1 Turn on the breaker between the inverter and the battery.
  • Page 16 If you can't find the WiFi signal or connect to the router, then A: For BH series inverter, it could connect lithium batteries which have compatibility with BH please try to reload Wi-Fi (please refer to "3.1 Wi-Fi Configuration").
  • Page 17: Disclaimer

    About Smart Meter And Power Limit Function Q: How to activate output power limit function? The BH series inverters are transported, used and operated under environmental and electrical conditions. Manufacturer has the right not to provide after-sales services or assistance under...
  • Page 18 Inverter detects a higher DC component in AC output DC Injection High Try to restart inverter, check if it still happens, if not, means it is just an occasional situation or contact GoodWe. EEPROM R/W Failure Caused by a strong external magnetic field etc.
  • Page 19: Technical Parameters

    4.4 TECHNICAL PARAMETERS AND CERTIFICATES Technical Data GW3K-BH GW3600-BH GW5000-BH GW6000-BH General Data TECHNICAL PARAMETERS OF BH INVERTER Over voltage category DC II: ACIII Technical Data GW3K-BH GW3600-BH GW5000-BH GW6000-BH Operating Altitude (m) 4000 Battery Input Data Cooling Nature Convection Battery Type Li-lon Li-lon...
  • Page 20: Quick Check List To Avoid Danger

    Zref: Moisture Location Category Definition RA=0, 24; XA=j0,15 at 50Hz; Level RN=0, 16; XN=j0,10 at 50Hz Moisture Parameters 4K4H 4.6 Quick Check List To Avoid Danger Temperature Range 0~+40℃ -33~+40℃ ~20~+55℃ 1. Inverter cannot be installed near flammable, explosive or strong electro-magnetic equipment, please refer to "2.3.1 Select Mounting Location".