Turbofiller Rinsing; Operating The Control Unit While Spraying (Evc Operating Unit Only); Before Returning To Refill The Sprayer - Hardi MASTER PRO VHH Instruction Book

Table of Contents

Advertisement

5 - Operation

TurboFiller rinsing

Rinsing the TurboFiller and chemical containers are done in the
following two ways:
When TurboFiller lid is open
For cleaning empty containers. Put container over the rotating flushing
nozzle in the middle of the TurboFiller so that the nozzle is inside the
container. Press the Chemical Container Cleaning lever and the
TurboFiller suction valve at the same time to activate the flushing nozzle
in the middle of the TurboFiller and empty out the TurboFiller rinsing
liquid.
When TurboFiller lid is closed
Use the Chemical Container Cleaning lever to rinse the hopper after filling of chemicals has ended. Press the Chemical
Container Cleaning lever and the TurboFiller suction valve at the same time to activate the flushing nozzle in the middle of
the TurboFiller and empty out the TurboFiller rinsing liquid. Do this 3 times and after the last flushing open the lid to inspect
if the TurboFiller is empty. If not, close the lid again and press the TurboFiller suction valve until the TurboFiller is empty.
μ
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying again to be sure it is clean before
spraying other crops that may be sensitive to the chemicals just used. See section "Cleaning" on page 52 for details.

Operating the control unit while spraying (EVC operating unit only)

The switches of the spray control unit control the following functions:
1. Power ON/OFF. Turns the spraybox power on or off.
2. Spray pressure regulation. Regulates the main spray pressure.
3. Main valve ON/OFF. Turns all sections on or off. Lever up is OFF and
down is ON.
4. End nozzle (Left/OFF/Right). If end nozzles are fitted, they can be
turned on for each side. Middle position is OFF.
5. Foam marker blob interval. Regulates the blob interval for the
optional foam marker.
6. Foam marker (Left/OFF/Right). Turns the optional foam marker on
for each side. Middle position is OFF.
7. Section valves. Turns single sections on or off. Lever up is OFF and down is ON.
8. Optional function (A/OFF/B). If extra equipment is added, it can be controlled from here. Middle position is OFF.
• In order to close the entire boom, switch main ON/OFF (3) to OFF position. This returns the pump output to the tank
through the return system. The diaphragm Non-drip valves ensure instantaneous closing of all nozzles.
• In order to close one or more sections of the boom, switch the relevant distribution valve (7) to off position (upwards).
The pressure equalisation ensures that the pressure does not rise in the sections that remain open.
• On the sprayer the suction valve should be turned toward "Suction from Main tank" and the pressure valve should be
turned toward "Spraying". Turn the agitation valve to "Agitation" if necessary.

Before returning to refill the sprayer

If the sprayer is to be refilled at the farm or at a fixed filling place without a filling space with hard surface and drain to closed
reservoir, the sprayer should be rinsed before returning to refill.
Dilute the residues of the spraying circuit, and spray it on the crop. Then rinse the sprayer on the outside with the External
Cleaning Device before returning to the farm.
μ
ATTENTION! Always follow local legislation in force at any time.