Programming Flowchart

Change
Select Output Protocol
Master Code
1
1
Enter New
Master Code
Single
Press 6 Digits
Wiegand
Select Type of Wiegand
2
1
2
3
4
Wiegand
Wiegand
Wiegand
Wiegand
26bit
30bit
34bit
40bit
Direct Menu exit
Entering Menu is always done with B + 000000 if the
Master Code is not changed.
Submenu 1 - Change Master Code. The Master Code
must be 6 digits. After enrolling new Master Code the
CV-920 automatically exits the Menu and the new master
code must be typed to enter the menu.
Submenu 2 - Select Type of Wiegand. With this the
Keypad can be adjusted to send 4 different Wiegand
Outputs. The Wiegand selected must be the same as the
controller's Wiegand Input that the CV-920 Keypad is
being connected to. Example: If you use a controller that
recognizes Wiegand 34bit, then enter the menu of CV-920,
press 2, then press 3.
Submenu 3 - Select Output Protocol. The Keypad can
send the Code by different Protocols. Use "Single Wiegand"
when connected to third party controllers. When "Single
Wiegand" is selected, what is typed on the Keypad is
sent as a Wiegand Number. Use Double Wiegand when
connected to CV-350, use Clock&Data when connected to
controller with Clock & Data input.
Submenu 4 - PIN Code Length. If "0" is selected, then
any PIN Code with any length can be sent, but the PIN Code
must be followed with "A" for confirmation ( ex. 123 + A).
If 1 to 8 is selected the PIN Code length is determinated by
the number selected.
Enter "Master Code"
1 small beep + 1 long beep + Orange LED is 'ON'
3
3
2
1
Wiegand
Double
Clock &
26bit
Wiegand
Data
normal
PIN Code Length
4
0
1 - 8
for any length
for lengths
with "A"
between
in the end
1 to 8 digits
Press "A" to validate and exit the menu
B + 000000
No
Error Beep
Validation OK?
(3 short beeps)
Yes
Presets
6
3
2
4
Wiegand
Wiegand
Wiegand
34bit
34bit
26bit
normal
CV-350
CV-350
Site Code Length
7
1
2
Site Code
Site Code
No Site
between
Code
0 to 15
(orange LED OFF)
Submenu 6 - Presets. The Presets are a set of
preprogrammed parameters for easy programming.
6-1 "Wiegand 26bit Normal" - Type: Wiegand 26bit;
Output: Single Wiegand; PIN Length: 4 digits;
Entry Mode: Card or PIN Code
6-2 "Wiegand 34bit Normal" - Type: Wiegand 34bit;
Output: Single Wiegand; PIN Length: 4 digits;
Entry Mode: Card or PIN Code
6-3 "Wiegand 34bit CV-350 Mode" - Type: Wiegand
34bit; Output: Double Wiegand; PIN Length: 4
digits; Entry Mode: Card or PIN Code
6-4 "Wiegand 26bit CV-350 Mode" - Type: Wiegand
26bit; Output: Double Wiegand; PIN Length: 4
digits; Entry Mode: Card or PIN Code
Presets 6-3 and 6-4 to be used always when CV-920
is connected to CV-350 firmware ver.2.42 or higher.
Submenu 7 - Site Code Length. Set the code length sent
to Host. Defaul is "0". To be used only in specific cases.
Submenu 8 - Enter Site Code. Put the site code always in
5 digit format (ex. 00170).
Submenu 9 - Backlight. Turns ON/OFF the backlight.
Page 4 of 5
CV-920 Series
Enter Site
Code
8
5 digits
Backlight
3
4
0
Site Code
Backlight
between
between
OFF
0 to 255
0 to 65535
9
1
Backlight
ON

Advertisement