Wiring Diagram - Amana AVPEC Series Installation & Operating Instructions Manual

Hide thumbs Also See for AVPEC Series:
Table of Contents

Advertisement

28 WIRING DIAGRAM

NOTE: THESE INSTRUCTIONS ARE SPECIFICALLY FOR AVPEC MODELS. DO NOT ATTEMPT TO APPLY THESE
DIAGRAMS FOR ANY OTHER MODELS.
(SEE NOTE 4)
GROUND LUG
INSTALLING
WH
AUX ALARM
(ALARM)
(SEE NOTE 8)
BR
BL
HEATER KIT
OUTPUT
NOTES:
1. PLACE RED WIRES ON 208 V TERMINAL OF
2-TRANSFORMER (TR1/TR2) FOR 208 VAC
OPERATION.
2. MANUFACTURER'S SPECIFIED REPLACEMENT
PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRES AS
SUPPLIED WITH THIS UNIT MUST
BE REPLACED, IT MUST BE REPLACED
WITH WIRING MATERIAL HAVING A
TEMPERATURE RATING OF AT LEAST 105°C.
USE COPPER CONDUCTORS ONLY.
4. UNIT MUST BE PERMANENTLY GROUNDED
AND CONFORM TO N.E.C ANDLOCAL CODES.
5. TO RECALL THE LAST 6 FAULTS, MOST
RECENT TO LEAST RECENT, DEPRESS
FAULT RECALL BUTTON FOR MORE THAN 2
SECONDS WHILE IN STANDBY (NO THERMOSTAT
INPUTS)
6. YELLOW STATUS LED PROVIDES NETWORK
STATUS.GREEN RX LED INDICATES NETWORK
TRAFFIC
7. DISCARD CONNECTOR PL1 WHEN
INSTALLING OPTIONAL HEAT KIT.
8. REMOVE SHORTING PLATE FROM THE AUX
SWITCH TERMINAL WHEN INSTALLING AUX
ALARM SWITCH.
9. USE N.E.C CLASS 2 WIRE.
208/230
TO
VAC
HEATER KIT
(SEE NOTE 7)
RD
BK
PL1
9
8
7
6
4
3
5
2
1
PL2
BK
RD
208
208
230
VAC
VAC
COM
VAC
COM
RD
BK
TR2
(SEE NOTE 1)
BK
RD
24VAC
24VAC
PU
YL
BL
RD
3
4
5
8
9
10
11
12
1
2
6
7
~ ~
AUX ALARM
AUX ALARM
(ALARM)
(ALARM)
J19
GR
~ ~
TH1
TR1
J19
TB1
TB2
F1U
FH1
FH2
VR1
C1
_
+
~
~
D1
C2
C4
C62
F2U
FH3
FH4
L1
K3
K1
PB3
PB2
K2
PB1
U6
J20
J6
J7
J6
J7
EEV
YL
BK
GY
RD
OR
EEV
M
M
THERMISTOR
THERMISTOR
COIL
(HEAT EXCHANGER 1,2)
(HEAT EXCHANGER 1,2)
INTEGRATION
TYPE
ECM MOTOR
BK
RD
230
VAC
FAN
TR1
(SEE NOTE 1)
MOTOR
RD
BK
GY
BL
PL3
PL4
RD
BK
THERMOSTAT
OUTDOOR UNIT
YL
W
GR
BL
RD
GYBK
J2
J1
L5
R13
R25
J13
U1
U7
B11
U9
J8
J9
J16
J17
J18
J18
INDOOR UNIT
PCB
PRESSURE
SENSOR
INTEGRATED CONTROL:
LOW VOLTAGE
LOW VOLTAGE FIELD
HIGH VOLTAGE
HIGH VOLTAGE FIELD
JUNCTION
TERMINAL
INTERNAL TO
RESISTOR
OVERCURRENT
PROT. DEVICE
PLUG CONNECTION
EQUIPMENT GND
FIELD GROUND
24
L1
GRND
DISCONNECT
INDOOR
AIR
CIRCULATOR
BLWR
208/230 VAC
L1
FUSE 3 A
TH2
R
24 VAC
EH1
HEAT 1 COIL/R1
C
EH2
HEAT 2 COIL/ R2
AUX IN
CONDENSATE SWITCH
G
AUX OUT
TO
MICRO
W
+VDC (1)
RX (2)
Y
TX (3)
GRND (4)
DEHUM
TR2
COM
INTEGRATED CONTROL MODULE
COLOR CODES:
BL - BLUE
RD - RED
COMPONENT CODES:
YL - YELLOW
PL1, PL2
OR - ORANGE
TL
BK - BLACK
TR
GY - GREY
F1U, F2U
BR - BROWN
PL3, PL4
GR - GREEN
PU - PURPLE
WH - WHITE
L2
GRND
L2
40 VA
TRANSFORMER
INDOOR
AIR
CIRCULATOR
BLWR
GRND
POWER/HEATER
CONNECTOR
THERMAL LIMIT
TRANSFORMER
FUSE LINK
TRANSFORMER
CONNECTOR
0140A00723-C

Advertisement