24 Electric Air Cleaner
The control is equipped with an Accessory Relay and a
pair of ¼ inch accessory terminals which is normally open,
labeled EAC-IN and EAC-OUT (see accessory contacts
graphic). The Accessory Relay is configured to close any-
time the blower is running. A closed relay means the two ter-
minals will have continuity between them (the control does
not energize these contacts). It is recommended to utilize
24VAC with these terminals and limit the current to 1A.
FIGURE 22
DEHUMIDIFICATION TIPS
For effective dehumidification operation:
Ensure "Dehum" is ON through the CoolCloud Phone
Application.
Verify the cooling airflow profile is set to "Profile D".
- By default "Dehum" is ON and the cooling airflow
profile is set to "Profile D".
For additional dehumidification control, airflow settings
are field adjustable and can be fine-tuned to a value that
is comfortable for the application from a range of +15%
to -15%.

25 MAX AIRFLOW TABLE

Model
AVPEC25B14
AVPEC29B14
AVPEC35B14
AVPEC37B14
AVPEC33C14
AVPEC31C14
AVPEC37C14
AVPEC39C14
AVPEC37D14
AVPEC49C14
AVPEC49D14
AVPEC59C14
AVPEC59D14
AVPEC61D14
NOTE: The System will not provide airflows above the max
airflow values.