22 Accessory Control (Humidifiers, Dehumid-
ifiers, Ventilators)
If an external humidifier, dehumidifier or ventilator is in-
stalled, it may require airflow from the HVAC system to func-
tion properly.
1. Make sure the installed 24VAC thermostat is capable
of controlling the accessory or accessories.
2. Connect the appropriate accessory control wires to
the accessory devices from the thermostat (see ther-
mostat manual for connection and setup instructions).
3. If the thermostat is capable of providing a continuous
fan call (G signal) during accessory operation, make
sure to connect the thermostat G terminal to the G ter-
minal on the indoor unit. Setup thermostat to ensure G
signal is energized during accessory operation.
FIGURE 20
4. Select the appropriate fan only airflow for the acces-
sory using the indoor unit push button menus or the
CoolCloud HVAC phone application.
5. Using the thermostat, independently test each acces-
sory in addition to the independently testing continu-
ous fan mode.

23 Ramping Profiles

The variable-speed circulator offers four different ramping
profiles. These profiles may be used to enhance cooling
performance and increase comfort level. Select the desired
ramping profile using the CoolCloud phone application or
the push button menus.