dataFEED Gateway - User Manual
6 Service Settings
The Service Settings view allows to configure common dataFEED Gateway settings.
These settings are described in the following sections:
36
Time Settings
36
Reset
37
Firmware Update
Backup and Restore
38
User Password
38
micro SD Card
39
Support
6.1 Time Settings
The Time Settings view allows to configure the dataFEED Gateway system time.
Local time is not supported by the dataFEED Gateway. All time entries have to be entered as UTC time.
The system time can be synchronized by NTPv4 [RFC 5905], either from an NTP server within your LAN network or
from some Internet NTP server (e.g. 0.pool.ntp.org). In the later case you need to ensure that the UDP port 123 is
not blocked by a firewall.
To enable the NTP usage, activate the Obtain time automatically checkbox and enter the IP address or the host
and domain name of the NTP server into the NTP Server Address input field.
With NTP is enabled on the dataFEED Gateway other devices in your network can access the dataFEED Gateway as
NTP server.
Saving and applying settings
1.
Click the Save button to save your settings.
A hint will appear reminding you that the application of some other settings is pending:
2.
Click at this link. Your settings will be applied.
Depending on the number of modified settings this process may take some time before being completed.
3.
A message in the upper window part will inform you about the successful modification(s).
6.2 Reset
The Reset view resets different dataFEED Gateway aspects.
Gateway restart
Click the Reboot button in the Hardware reboot section to perform a dataFEED Gateway hardware reboot.
The hardware reboot also causes all new configurations to be taken on.
Reset configuration to default values
Select the IT Settings checkbox, if the dataFEED Gateway configuration of the IT network needs to be reset.
Select the Machine Settings checkbox, if the dataFEED Gateway configuration of the Machine network needs
to be reset.
Click the Reset configuration to default values button to reset the selected part(s) of the configuration to
the firmware default values.