Maintenance; Maintenance Schedule; Engine Service Cover; Air Filter Maintenance - Westinghouse iGen4500 User Manual

Digital inverter
Hide thumbs Also See for iGen4500:
Table of Contents

Advertisement

Available languages

Available languages

MAINTENANCE

MAINTENANCE SCHEDULE

Regular maintenance will improve performance and
extend the service life of the generator. Follow the hourly
or calendar intervals, whichever occurs first. More frequent
service is required when operating in adverse conditions
as noted below.
Before Each Use
Check engine oil
After First 25 Hours or First Month
Change engine oil
After 50 Hours or Every 6 Months
Change engine oil
Clean air filter
After 100 Hours or Every 6 Months
Inspect/clean spark arrestor
Inspect/clean spark plug
Replace fuel filter
Inspect/adjust valve clearance
After 300 Hours or Every Year
Replace spark plug
Replace air filter
Change oil every month when operating under heavy
1
load or in high temperatures.
Clean more often under dirty or dusty conditions.
2
Replace air filter if it cannot be adequately cleaned.
Recommend service to be performed by authorized
3
Westinghouse service dealer.
MAINTENANCE REPLACEMENT PARTS
Description
Foam air filter
Oil drain plug crush washer
Spark arrestor
Battery
Spark plug
1
2
3
3
Part Number
5691
94007
6790
511019
• Torch - F7RTC
• NGK - BPR7ES
• Bosch - WR5D
• Autolite - 62

ENGINE SERVICE COVER

Remove the engine service cover to access the air filter,
carburetor, and spark plug. Remove the cover screws
then pull the cover straight out with both hands to prevent
damage to the grommet posts on the cover.
Cover Screws (5x)
Internal Push-In Grommet Posts

AIR FILTER MAINTENANCE

Fire hazard. Never use gasoline or other flammable
solvents to clean the air filter. Use only household
detergent soap to clean the air filter.
The air filter must be cleaned after every 50 hours of use or
six months (frequency should be increased if the generator
is operated in a dusty environment).
1. Place the generator on a level surface and allow the
engine to cool for several minutes.
2. Remove the engine service cover.
3. Turn the knobs on the air cleaner cover to the unlocked
position. Tip the cover down to remove.
Note: The air filter element is oil soaked. Use an
appropriate cleaning container.
Westinghouse Outdoor Power Equipment, LLC | 19
WARNING

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Igen2200Igen2500