GENERAL DATA - RKHL
NOM. SIZES 7.5-10 TON [26.4 & 35.2 kW] ENERGYSTAR COMPLIANT MODELS
Gross Cooling Capacity Btu [kW]
1
EER/SEER
Nominal CFM/AHRI Rated CFM [L/s]
AHRI Net Cooling Capacity Btu [kW]
2
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
IEER
Heating Performance (Gas)
Net System Power kW
3
Heating Input Btu [kW] (1st Stage / 2nd Stage)
4
Heating Output Btu [kW] (1st Stage / 2nd Stage)
Temperature Rise Range ºF [ºC] (1st Stage / 2nd Stage)
Steady State Efficiency (%)
No. Burners
No. Stages
Compressor
Gas Connection Pipe Size in. [mm]
Outdoor Sound Rating (dB)
No./Type
Outdoor Coil - Fin Type
5
Tube Type
MicroChannel Depth in. [mm]
Face Area sq. ft. [sq. m]
Indoor Coil - Fin Type
Rows / FPI [FPcm]
Tube Type
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Outdoor Fan - Type
Drain Connection No./Size in. [mm]
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
No. Motors/HP
Indoor Fan - Type
Motor RPM
No. Used/Diameter in. [mm]
Drive Type
No. Speeds
No. Motors
Motor HP
Motor RPM
Potable Water Heat Recovery
Motor Frame Size
Heat Exchanger Type
Material
No. Flat Plates
Water Pump - Type
Unit Water Connections No./Size in. [mm]
Drive Type/No. Speeds
Housing Material
GPM [L/s]
Head Pressure ft. H2O [kPa]
Motor HP
Filter - Type
Motor RPM
Furnished
(NO.) Size Recommended in. [mm x mm x mm]
Refrigerant Charge Oz. (Sys. 1/Sys. 2) [g]
Weights
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
NOTES:
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. AHRI capacity is net and includes
the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner Equipment certification program, which is
based on AHRI Standard 210/240 or 360.
2. EER and/or SEER are rated at AHRI conditions and in accordance with DOE test procedures.
3. Integrated Energy Efficiency Ratio (IEER) is rated in accordance with AHRI Standard 210/240 or 360.
4. Heating Performance limit settings and rating data were established and approved under laboratory test conditions using American National Standard Institute standards. Ratings shown are for
elevations up to 2000 feet. For elevations above 2000 feet, ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
5. Outdoor Sound Rating shown is tested in accordance with AHRI Standard 270.
8
D180CL25E
D180CL35E
182,000 [53.33]
182,000 [53.33]
12.4/NA
12.4/NA
6000/5800 [2831/2737]
6000/5800 [2831/2737]
176,000 [51.57]
176,000 [51.57]
130,400 [38.21]
130,400 [38.21]
45,600 [13.36]
45,600 [13.36]
13
13
14.23
14.23
125,000/250,000 [36.62/73.25]
175,000/350,000 [51.27/102.55]
101,500/203,000 [29.74/59.48]
142,000/284,000 [41.61/83.21]
15-45 [8.3-25] / 15-45 [8.3-25]
30-60 [16.7-33.3] / 30-60 [16.7-33.3]
81
81
10
14
2
2
0.75 [19]
0.75 [19]
2/Scroll
2/Scroll
91
91
Louvered
Louvered
MicroChannel
MicroChannel
1 [25.4]
1 [25.4]
50.8 [4.72]
50.8 [4.72]
1 / 23 [9]
1 / 23 [9]
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
26.67 [2.48]
26.67 [2.48]
2 / 18 [7]
2 / 18 [7]
TX Valves
TX Valves
1/1 [25.4]
1/1 [25.4]
Propeller
Propeller
3/24 [609.6]
3/24 [609.6]
Direct/1
Direct/1
10000 [4719]
10000 [4719]
3 at 1/3 HP
3 at 1/3 HP
1075
1075
FC Centrifugal
FC Centrifugal
2/18x9 [457x229]
2/18x9 [457x229]
Belt (Adjustable)
Belt (Adjustable)
Single
Single
1
1
3
3
1725
1725
56
56
Vented Double-Wall Flat Plate
Vented Double-Wall Flat Plate
Cu Brazed Stainless Steel
Cu Brazed Stainless Steel
50
50
2/1.625 [41.3]
2/1.625 [41.3]
Centrifugal
Centrifugal
Direct/1
Direct/1
Stainless Steel
Stainless Steel
30 [1.89]
30 [1.89]
25 [74.7]
25 [74.7]
1/3
1/3
3450
3450
Disposable
Disposable
Yes
Yes
(8)2x25x20 [51x635x508]
(8)2x25x20 [51x635x508]
171/201 [4848/5698]
171/201 [4848/5698]
2027 [919]
2040 [925]
2154 [977]
2167 [983]
D180CM25E
D180CM35E
Continued ->
182,000 [53.33]
182,000 [53.33]
12.4/NA
12.4/NA
6000/5800 [2831/2737]
6000/5800 [2831/2737]
176,000 [51.57]
176,000 [51.57]
130,400 [38.21]
130,400 [38.21]
45,600 [13.36]
45,600 [13.36]
13
13
14.23
14.23
125,000/250,000 [36.62/73.25]
175,000/350,000 [51.27/102.55]
101,500/203,000 [29.74/59.48]
142,000/284,000 [41.61/83.21]
15-45 [8.3-25] / 15-45 [8.3-25]
30-60 [16.7-33.3] / 30-60 [16.7-33.3]
81
81
10
14
2
2
0.75 [19]
0.75 [19]
2/Scroll
2/Scroll
91
91
Louvered
Louvered
MicroChannel
MicroChannel
1 [25.4]
1 [25.4]
50.8 [4.72]
50.8 [4.72]
1 / 23 [9]
1 / 23 [9]
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
26.67 [2.48]
26.67 [2.48]
2 / 18 [7]
2 / 18 [7]
TX Valves
TX Valves
1/1 [25.4]
1/1 [25.4]
Propeller
Propeller
3/24 [609.6]
3/24 [609.6]
Direct/1
Direct/1
10000 [4719]
10000 [4719]
3 at 1/3 HP
3 at 1/3 HP
1075
1075
FC Centrifugal
FC Centrifugal
2/18x9 [457x229]
2/18x9 [457x229]
Belt (Adjustable)
Belt (Adjustable)
Single
Single
1
1
5
5
1725
1725
184
184
Vented Double-Wall Flat Plate
Vented Double-Wall Flat Plate
Cu Brazed Stainless Steel
Cu Brazed Stainless Steel
50
50
2/1.625 [41.3]
2/1.625 [41.3]
Centrifugal
Centrifugal
Direct/1
Direct/1
Stainless Steel
Stainless Steel
30 [1.89]
30 [1.89]
25 [74.7]
25 [74.7]
1/3
1/3
3450
3450
Disposable
Disposable
Yes
Yes
(8)2x25x20 [51x635x508]
(8)2x25x20 [51x635x508]
171/201 [4848/5698]
171/201 [4848/5698]
2056 [933]
2069 [938]
2183 [990]
2196 [996]