SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
SOUND
CAUSE
LOUD, INTERRUPTED*
FIRE ALARM.
Touchpad & External
LOUD, CONTINUOUS*
BURGLARY/AUDIBLE
EMERGENCY ALARM.
Touchpad & External
ONE SHORT BEEP
a. SYSTEM DISARM.
(not repeated)
b. SYSTEM ARMING ATTEMPT
Touchpad only
WITH AN OPEN ZONE..
c. BYPASS VERIFY.
ONE SHORT BEEP
a. SYSTEM IS IN TEST MODE.
(once every 40 seconds)
b, LOW BATTERY AT A
Touchpad only
TRANSMITTER.
TWO SHORT BEEPS
ARM AWAY.
Touchpad only
THREE SHORT BEEPS
a. ARM STAY OR INSTANT.
Touchpad only
b. ZONE OPENED WHILE SYSTEM
IS IN CHIME MODE.
RAPID BEEPING
a. TROUBLE.
Touchpad only
b. MEMORY OF ALARM.
c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRING FAIL.
SLOW BEEPING
a. EXIT DELAY WARNING (if
programmed).
Touchpad only
b. ENTRY DELAY WARNING.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring .

(CUSTOM ENGLISH DISPLAY TOUCHPADS)

D I S P L A Y
FIRE is displayed; descriptor of zone in alarm is displayed. If a fire alarm is
manually activated, zone number 95 will be displayed.
ALARM is displayed. If programmed, descriptor of zone in alarm is also displayed
a. DISARMED/READY TO ARM is displayed.
b. The number and descriptor of the open protection zone is displayed.
c. Numbers and descriptors of the bypassed protection zones are displayed (One
beep is heard for each zone displayed). Subsequently, the following is displayed:
DISARMED BYPASS Ready to Arm.
a. Opened Zone identifications will appear.
b. LO BAT displayed with description of transmitter.
ARMED AWAY displayed. Red ARMED indicator lit.
a. ARMED STAY or ARMED INSTANT displayed. Red ARMED indicator lit.
b. CHIME displayed, descriptor of open protection zone will be displayed if the [ ]
key is pressed.
a. CHECK displayed. Descriptor of troubled protection zone is displayed.
b. FIRE or ALARM is displayed; descriptor of zone in alarm is displayed.
c. SYSTEM LO BAT displayed.
d. BELL FAILURE is displayed.
a. ARMED AWAY is displayed along with You May Exit Now.
b. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. Exceeding the
delay time without disarming causes alarm.