System Reset; System Startup From Omc; Overview; Installation Procedure - Alcatel-Lucent OXO Connect Series Installation Manual

Table of Contents

Advertisement

Chapter
6
The message "Date and time must be programmed" is displayed when the "Date" and "Time" fields
are empty or contain the default values.

6.1.15 SYSTEM RESET

This menu is used to confirm resetting the system.
Finish
After the reset, your system will operate with the new parameters entered.

6.2 System Startup from OMC

6.2.1 Overview

OMC is the PC application used to program the OXO Connect system via a local connection (V24 or
LAN) or a remote connection (the PC modem is connected to the OXO Connect integrated modem via
the public network).
Three levels of programming are available using OMC:
Easy View is used for Wizard configurations, i.e. the essential parameters for starting the system.
EasyPlus View is used for wizard-type configurations with the extensions offered by the Advanced
key. This key opens a window which is equivalent to Expert View.
Expert View gives you unrestricted access to all the configuration possibilities.
The Wizard provides easy-to-use system programming, guiding the user step-by-step.

6.2.2 Installation procedure

6.2.2.1 Minimal PC Configuration
PC requirements: see Microsoft
Supported operating systems: refer to the Cross Compatibility
Hard disk: 300 MB (recommended for installation and operation)
Screen: 1024 x 768 pixels
1 mouse
1 serial port (connection to OXO Connect for data transfer)
1 Ethernet board (IP mode only; not required when there is a V24 serial port connection to OXO
Connect)
64K (1 B-channel), or 128K (2 B-channels) PPP-compatible ISDN modem, or V34 modem for
remote access
Note:
Before installing OMC, the framework .NET must be installed.
3EH21123USAA - Ed. 01 - April 2017 - Installation Manual
Start-Up
System reset; the display shows "System reset in progress"
®
requirements for Windows version
181/207