Chapter
4
4. Press OK. The set then goes back to its default display.
4.10 V24/CTI Interface Module
4.10.1 Hardware description
4.10.1.1 Overview
The V24/CTI Interface Module allows a Data Terminal Equipment (DTE) to be connected to the OXO
Connect, via a UA link, by means of an RS232 serial link (CTI port) or a V24 link.
The V24/CTI Interface Module can be used alone or combined with Digital Premium DeskPhones.
CTI port
The RS232 serial link carries signalling (up to 9600 bit/s) and allows telephone operations such as call
management and call monitoring. The audio part is carried out by the associated dedicated set.
V24 port
The V24 port is considered as a DCE and provides a capacity of 19200 bit/s (ECMA 102) for an
asynchronous V24 transmission. The electrical interface complies with the V28 recommendation of the
CCITT.
PCX
UAI Board
(or MIX board)
4.10.1.2 Compliant Standards
4.10.1.2.1 Safety Requirements
•
EN60950: European requirements
•
UL 1950: US requirements
•
CAN/CSA-C22.2 No 950-95: Canada
4.10.1.2.2 ECM
•
EN55022: Limits and methods of measurement of radio interference characteristics of information
technology equipment
•
EN55024: Limits and methods of measurement of immunity characteristics of information
technology equipment
•
FCC part15: US requirements
3EH21123USAA - Ed. 01 - April 2017 - Installation Manual
Installation and Cabling
DTE
UA link
Figure 4.10: V24/CTI Interface Module Configuration Example
V24: up to 19200 bit/s
CTI: up to 9600 bit/s
or
DCE
CTI
V24
UA link
UA
UA
V24/CTI
Interface Module
9 Series Set
108/207