Fill With Nitrogen - FIBRO 2486.22 Series Maintenance Instructions Manual

Gas spring ds
Table of Contents

Advertisement

2.4

Fill with nitrogen

Damage to the gas pressure spring if other resources are used.
Use the resources listed below for filling. The resources can be obtained from FIBRO GMBH.
1) Prepare the filling and checking equipment.
24/30
NOTICE
Pos.
Description
[A]
Filling and checking equipment
[B]
G1/8" filling adapter
[C]
Filling hose
Cylinder pressure reducer (optional)
A
Observe the operating instructions for the filling and checking equipment
2480.00.32.21.
Turn the small knob (a) to the left as far as it will go. This will move the release pin (b)
into the retracted position.
Close the outlet valve (c).
Screw the filling adapter onto the M6 thread on the fittings. In the process, ensure that
the washer seal is located on the M6 thread.
1.
B
G1/8"
a
Maintenance
Article number
2480.00.32.21
2480.00.32.11
2480.00.31.02
2480.00.32.07
C
b
c
Maintenance instructions Gas spring DS

Advertisement

Table of Contents
loading

Table of Contents