2.3.2
Evacuating gas pressure
High pressure
Serious injuries may result if the gas is not fully drained before removing the gas spring.
Only trained personnel with good product knowledge are permitted to carry out the activities
Always wear safety glasses when working on a gas spring.
Never bend directly over a valve. Never direct connections towards yourself or other per-
Do not allow any extreme forces to be exerted on the gas spring.
When filled, the gas spring is under high internal pressure and must be protected against
To maintain the maximum service life of the gas spring, always protect it against dirt, caustic
When clamping in a vice, always use protective jaws.
The procedure given below for draining the gas must be followed with care.
Evacuation instructions for the safe draining of gas
1
2
3
4
5
6
7
8
9
14/30
WARNING!
described.
sons.
damage.
liquids and abrasive dust.
NOTICE
1
2
Locking screw on service port
Cylinder pipe
Locking screw on fill opening
Valve
Warning tape
Maximum stroke
M8 T-Lever
G1/8" Valve tool
Valve tongs
Fig. 2-4 Parts of the DS gas spring / Tools required
7
6
5
8
9
4
3
Maintenance instructions Gas spring DS
Maintenance