7) After checking, turn the small knob to the left as far as it will go. The release pin moves into
8) Slowly open the knob on the outlet valve and bleed the fittings.
9) Unscrew the fittings from the gas spring by turning the large knob.
10) Unscrew the filling adapter.
11) Screw the G1/8" locking screw into the fill opening of the gas spring.
The locking screw has a sealing function and must always be fitted.
10/30
the retracted position and closes the valve.
Tighten using a tightening torque of 15 - 18 Nm (11-13 lb-ft).
8.
7.
9.
10.
Maintenance
11.
Maintenance instructions Gas spring DS