Specifications
General specifications
Find Quality Products Online at:
Display
3-3/4 digit (4000 count) LCD
Sampling rate
1 reading per second
Test ranges
Resistance: 4M, 40M, 400M4000M, 10G
Test Voltages: 250V, 500V, 1000V
AC/DC Voltage range
999V
Resistance range
9999
Lo Resistance range
40
Over range indicator
'OL' displayed when measurement exceeds range
Zero adjust
Automatic
Memory
Nine (9) data records
Low battery indicator
'BT' symbol displayed when battery voltage is low
Power source
Six (6) 1.5 'AA' batteries
Power consumption
20 to 95mA (depending upon function)
Fuse protection
0.5A / 600V fast blow fuse
Operating conditions
32 to 122
Dimensions
9.3 x 4.6 x 2.1" (235 x 116 x 54mm)
Weight
1.15 lbs (520g)
Safety ratings
Pollution degree 2; indoor use; CE marked;
Meets IEC 61010-1 and IEC 61557 standards
Category Rating
CAT III-1000V, CAT IV-600V