Audi R8 LMS 2018 Handbook page 15

Table of Contents

Advertisement

Technical Data
-
Extinguishant:
-
Filling pressure:
-
Operating pressure:
-
Net extinguishant weight:
-
Operating temperature range:
-
Discharge time:
-
Homologation number:
Checking the Extinguishing System
The fire extinguishing system must be checked and armed each time before an
event where the car is driven on the race track.
The following components must be checked:
-
Extinguishant reservoir:
 Operating pressure must not be less than 32.5 bar or exceed 41.5
bar
 The next inspection date must not be exceeded (see service interval
extinguishing system)
-
Control unit:
 Set the toggle switch on the control unit to the 'TEST' position
 The four LEDs should illuminate afterwards
 Small green LED
 BATTERY LED
 FIRE LED
 EXTING LED
 If the BATTERY LED does not glow, the two batteries must be
changed (see 'Changing Batteries').
 If one of the three remaining LEDs does not glow, the wiring loom
must be checked.
000 – Air Jack and Fire Extinguisher
Aerosol KD-A96
36.5 bar / 20 °C
Min. 32.5 bar
Max. 41.5 bar
0.5 kg
- 10 to + 60 °C
Approx. 5 seconds
EX.014.03 04/03
--> System active
--> Battery ok (charged)
--> Electric circuit to trigger ok
--> Electric circuit to detonator ok
Version 1 2016-01-01
15 / 113