Powering On The System - IBM Storwize V7000 Installation Manual

Expansion enclosure
Table of Contents

Advertisement

Figure 9. Sliding the cable retention bracket directly behind the power cord
7. Tighten the fastener around the plug.
8. Repeat the steps for each additional power cord.
9. Plug the power cords into a properly grounded electrical outlet. To provide

Powering on the system

You can use this procedure to power on an expansion enclosure and determine the
status of the system.
About this task
Attention: Do not operate the system when the drive assemblies are missing.
Drive assemblies that are missing disrupt the airflow; the drives do not receive
sufficient cooling. You must insert blank carriers into unused drive bays.
Powering on an expansion enclosure:
1. Power on the newly installed enclosures. Use the power switch on each of the
2. Use the information in Table 5 on page 16 to verify the state of the light
Figure 10 on page 16 shows the location of the LEDs on the power supply units in
the rear of the expansion enclosure.
power failure redundancy, plug the power cords for the individual power
supply units for each enclosure into separate power distribution units, if
possible.
two power supply units in the back of the expansion enclosure.
emitting diodes (LEDs) on the system. Verify that no faults are detected. Refer
to your system Information Center's Troubleshooting section.
Chapter 4. Installing the hardware
15

Advertisement

Table of Contents