This is the user's manual for your Scanwave device.
This document must be used together with the general
user's manual for SATELEC curing lamps.
I – DESCRIPTION
1.1 P
resentation
As symbolised in figure 1, ScanWave includes the
following components:
• The multi-fiber light guide, 45° curve, Ø7.5mm,
sterilizable (fig. 1-1).
• The handpiece (fig. 1-3) fitted with a protective cap
(fig. 1-2).
• Lithium-ion battery (fig. 1-4), assembled when
delivered.
• Charging base (fig. 1-5).
• Power supply.
• The main plugs (USA, AUS, EEC, UK).
• The rigid protection shield.
• Accompanying documentation.
On option:
• Kit of 5 flexible protective shields, sterilizable, Ø7,5 mm.
• Multi-fiber light guide, 45° curve, Ø 5,5mm,
sterilizable.
• Kit of 5 flexible protective shields, sterilizable, Ø5,5 mm.
1.2 t
echnical descriPtion
ScanWave is equipped with a Light-Emitting Diode
(LED) that emits blue visible light of a wavelength
between 390 and 505nm for the photopolymerization of
dental materials.
Scanwave incorporates a laser aiming system
with a wavelength of 655nm and a light intensity
of less than 1mV, allowing the light ray to be directed
with precision.
ATTENTION - LASER LIGHT - DIRECT EXPOSURE DANGEROUS
FOR EYES - CLASS 2 LASER UNIT
IEC –60825 standard-1 second edition 2007 - Safety of laser
devices - Max. power: 1mW - Pulse duration: duration
of user pressing button - Wavelength: 655nm
4 ● NG39EN020E ● 05/2013 ● (13) ● V5 ● J05451 ●User's Manual ScanWave
1.3 lcd
screen
The LCD screen is backlit and allows the display of the
different pieces of information required by the user.
2
4
As shown above, it comprises different zones identified
from top to bottom as follows:
• A text box displaying the curing mode selected. (1)
• A display in seconds of the duration of the selected
curing cycle. During operation, this countdown
display indicates the remaining activation time until
the current cycle is complete. (2)
• Three icons represent the type of light emission. (3)
Continuous light
Flashing light
Gradual light
• A battery charge level indicator symbolised by a
ladder with 0 to 5 levels. (4)
• A laser function activation indicator: LA. (5)
1.4 M
enu activation and selection
The handpiece comprises several control devices.
Two buttons located under the LCD screen can be used
to:
- Configure the required mode by pressing the left-
hand «M» Mode button (fig. 1-6)
- Select in this mode, the curing cycle to be used.
Right-hand «C» Cycle button (fig. 1-7)
The curing cycle is initiated by pressing the control
trigger located under the device (fig. 1-8) or the ON/
OFF button (fig. 1-9) located on the aluminium tip.
1.5 B
attery autonoMy
The charge level indicator shows the remaining battery
power. Its charge time is about 3 hours.
• When the battery is completely discharged, the LCD
1
3
5