B.2.3

Problems when using expansion cards

Problem
The device crashes during
startup
The device does not start up or
switches off immediately
SIMATIC IPC347G
Operating Instructions, 10/2020, A5E50059993-AA
Cause
Redundant I/O addresses
Redundant hardware interrupts
and/or DMA channels
Signal frequencies or signal
levels are not adhered to
Different pin assignment
Insufficient output of an external
power supply, e.g. UPS
A counter voltage is fed into the
device by connected or installed
expansion cards
Remedy
Check your computer configuration:
If the computer configuration corresponds to the
delivery state, contact your technical support
team.
In the case of a change in the configuration,
restore the delivery state. To do this, remove the
expansion card and restart the device. If the error
no longer occurs, the expansion card was the
cause of the fault. Replace this with a Siemens
expansion card or contact the supplier of the ex-
pansion card.
If the device still crashes, contact your technical
support team.
Use a powerful power supply.
Clarify the following with the supplier of the compo-
nent:
The component can be operated without an
external power supply.
The component can be reconfigured so that it
only uses the external power supply or that of the
device.
Technical support
B.2 Troubleshooting
117