2-1. Trouble Diagnosis
t
A failure may have occurred due to the submergence of this unit. Check the state of the water detection
sheet as required. (Refer to Section 1-4.)
2-1-1. Sound Is Not Output
START
Check if the radio wave is output using the receiver.
When this unit is moved close to the receiver, do the
RF level display and QL level display show the
maximum level?
Is the sound output when the
setting menu "Internal SG" is
used?
Check the following possible
causes and replace the parts.
Possible causes
1) AF harness disconnection: Check CN500 (TX-172 board) and CN4012 (CN-4148 board) or CN4002 (CN-4078 board).
2) Disconnection of AF harness: Replace the AF harness. (Refer to the Section 3-2-7.)
3) Failure of TX-172 board (failure of audio circuit): Replace the TX-172 board.
2-1-2. Remote Function Does Not Operate
When the RF remote function does not operate, refer to "4-2-4. RF Remote Performance Check".
DWT-B30
Section 2
Troubleshooting
No
Replace the DPR-396 board.
(Failure of signal processing
portion)
Yes
Internal SG: Instead of the sound input from the microphone head,
Yes
Replace the DPR-396 board.
(Failure of signal processing
portion)
The QL level display
does not show the
maximum level.
Refer to "2-1-3. Radio Wave
Is Not Output".
(Failure of RF circuit or
antenna portion)
the audio signal of 1kHz is generated in this unit.
No
Replacement procedure of DPR-396 board:
Refer to Section 3-2-5.
Replacement procedure of TX-172 board:
Refer to Section 3-2-4.
The RF level display
does not show the
maximum level.
2-1 (E)