CORNER HEARTH DIMENSIONS FLUE CLEARANCES DIAGRAM STANDARD DEFAULT TRIPLE SKIN FLUE KIT INSULATED ROOM SEAL FLUE KIT INSULATED ROOM SEAL FLUE KIT COMPLIANCE DATA BAY BX DIMENSIONS BAY BX PARTS LIST CHARNWOOD AUSTRALIA 10 YEAR GUARANTEE 23 Ref.BAY BX aus v1 01.21...
Have flue swept anually. Flue can be swept through stove. SERVICING Stove should be serviced by a professional at least once a year. LIGHTING AND CONTROLLING THE FIRE Suitable fuels for your Charnwood: Wood logs Unsuitable fuels: Petroleum coke Liquid fuel...
OPERATING INSTRUCTIONS ® Congratulations on becoming the owner of a Charnwood Bay BX LIGHTING Stove. Your stove has been approved to burn wood logs if it is used in accordance with these instructions. It is very important that you On initial lighting, the stove may smoke and give off an odour as the read and understand these instructions before using the stove.
OPERATING INSTRUCTIONS ® air holes in back bricks. Fig. 1 Stove controls Do not operate with the door open except as directed by the instructions as this can cause excessive smoke. ASH CLEARANCE For optimum wood burning, it is important to leave a layer of ash, around 1cm thick, on the base of the stove.
(see Fig. 3). Any sooty deposits should then be swept from the plate installation. and into the fire. Your Charnwood flue should be swept at least twice a year. It will Return the baffle plates to their correct position by reversing the generally be possible to sweep the flue through the appliance.
OPERATING INSTRUCTIONS ® In situations where it is not possible to sweep through the appliance stove very slowly for long periods. the installer will have provided alternative means, such as a flue If blackening of the glass still occurs check that all flue connections access door.
If you need further help with your Charnwood then your Installer will be able to provide the answers to most questions. Your Local Charnwood Dealer has a great deal of experience and will also be able to provide helpful advice. Further help is available from Pivot...
HEARTH AND FIRE SURROUND External air supply kits are available please contact Charnwood for The stove must stand on a fireproof hearth and must not be situated more information. Instruction sheet ref: TIS 120...
CONNECTIONS TO FLUES The Bay BX must be connected to the flue using flue pipe of 150mm (6”) diameter : and is tested for both Air Cooled triple Skin Flue Kits & Room Seal Insulated flue Kits that have been tested to AS/...
STANDARD HEARTH DIMENSIONS ® DEFAULT HEARTH TO WALL BAY BX MIN. DIMENSIONS DEFAULT HEARTH MIN. DIMENSIONS TO WALL 705mm 830mm 905mm 905mm 300mm 300mm 70mm 70mm 125mm NON-COMBUSTIBLE MATERIAL Minimum thickness: 24mm Minimum thermal resistivity: 0.026 Installed in accordance with AS/NZS 2918:2018 3.3.2...
FLUE CLEARANCES DIAGRAM ® Summary of minimum height of flue sytem exit requirements from AS/NZS 2918:2018 6000 3000 More than 3000 or less 600 min. 3000 1000 min. if clear within 3000 of flue top Increase as necessary until nothing within 6000 of flue top Any nearby structure More than 3000 3000...
Charnwood Bay BX Australia Parts List BAY BX PARTS LIST Issue A ® Item Part No. Description Item Part No. Description 001/XR010 Firebox 008/XR012 Control Knob 002/BT001 Door Casting 004/XR072 Air Control Plate 006/BT018 Glass 008/XR073 Air Control Gasket 008/MR047...
• The following conditions apply: • If any part fails due to manufacturing or material defect within the guarantee period Charnwood will, free of charge, either repair or replace the part at their discretion. The decision of Charnwood is final.