Section 1 Trouble Shooting; Self-Diagnosis Function; Note On The Function Of Boards; Self-Diagnosis Code Table - Sony ZV-1 Service Manual

Hide thumbs Also See for ZV-1:
Table of Contents

Advertisement

1-1. Self-diagnosis Function

1-1-1. Self-diagnosis Function
If an error occurs in this unit, the self-diagnosis function starts working and a code consisting of one alphabet and a fourdigit number
appears on the LCD. Classification of persons in charge, classification of faulty blocks, and details of errors can be checked by
referring to this indication of five alphanumeric characters in the self-diagnosis code table.
The history of past errors can be checked in "Usage and Diag record" on the DATA tab of the Adjust Manual.
The self-diagnosis function is also described in the operation manual.

1-1-2. Note on the Function of Boards

The boards and functions used in this model are mentioned in the following table.
Board
Function
BT board
Battery
CD board
Imager
MIS board
Multi interface shoe
MS board
Wireless LAN module, Card slot
PD board
LCD
RE board
LCD rotation detect sensor, LCD open/close detect sensor
RL-1065 board
6 axial acceleration sensor, Switch
RL-1066 board
Microphone, Speaker
SY board
PITCH/YAW angular velocity sensor, Lens control, CPU, power control, Other function

1-1-3. Self-diagnosis Code Table

Self-diagnosis Code
Repaired
Block
by:
Function
C
13
01
C
32
01
C
32
60
E
41
00
E
61
00
E
61
10
Section 1
Trouble Shooting
Detailed
Symptom/State
Code
Memory card is unformatted or
memory card is broken.
Trouble with hardware
Difficult to adjust focus
(Cannot initialize focus)
Abnormality of the wireless LAN
module or CPU
Difficult to adjust focus
(Cannot initialize focus)
Zoom operations fault
(Cannot initialize zoom lens)
Correction
Format the memory card.
Insert a new memory card.
Turn power off and turn power on again.
Turn power off and turn power on again. When this error
is not cleared, the focus control signal for the lens block
may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
The peripheral circuit of between CPU and wireless LAN
module may be faulty.
Replace the board that contains this peripheral circuit.
Turn power off and turn power on again. When this error
is not cleared, the focus control signal for the lens block
may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
Turn power off and turn power on again. When this error
is not cleared, operate the zoom lever and check
following items.
When zooming is performed, the zoom control signal
for the lens block may be faulty.
When zooming is not performed, the zoom motor
drive circuit may be faulty.
Check whether this error is due to the lens or the board.
Replace the faulty lens or board.
Sony CONFIDENTIAL
For Authorized Servicer
Continued