Emerson Sensi Predict kit Installation & Activation Manual

Emerson Sensi Predict kit Installation & Activation Manual

Indoor kit

Advertisement

Quick Links

INDOOR KIT INSTALLATION & ACTIVATION GUIDE
The Sensi™ Predict kit is designed for conventional, residential HVAC equipment (furnace, AC, & heat
pumps) in homes that have Internet access. The Sensi Predict system acts as a monitor only and does not
provide any HVAC control.
As the installing technician, it is your responsibility to know what requirements, hazards and precautions
exist, and to install the monitoring system in a safe manner.
Do not alter the mounting of parts within the HVAC equipment.
•  Installer must be a qualified technician, familiar
with installation and service of HVAC equipment,
associated wiring, and electrical codes.
•  Follow all local and national
codes and ordinances.
•  The Sensi Predict power transformers are
designed for connection to 120VAC or 240VAC volt
electric powers within existing HVAC chassis only.
•  After installation or replacement, follow the HVAC
manufacturer's recommended instructions to
ensure proper operation of the HVAC equipment.
•  Labeling any HVAC wires that need
to be disconnected during the
installation is recommended.
OPERATING CONDITION:
Operating Temp -40°F to 158°F
Storage Temp -40°F to 176°F
ELECTRICAL RATING:
Line Voltage Inputs 90-132VAC / 180-
264VAC
Frequency 60Hz
Control Line Voltage 24VAC at 60Hz
The Sensi Predict Contractor PRO Portal can be accessed at sensipredictpro.com
For login support, contact your office administrator. For support within the PRO Portal, call 1-877-424-1715.
WARNING
FAILURE TO COMPLY WITH THE
FOLLOWING WARNINGS COULD RESULT
IN PERSONAL INJURY OR PROPERTY
DAMAGE
SHOCK HAZARD
• Disconnect electrical power supplies before
installation or servicing.
FIRE HAZARD
• Do not exceed specified voltages. Only
power transformers should be connected
to line voltage. All other wires shall only
connect to low voltage (24 VAC). Safely
route and secure all wiring after installation.
• Protect powered devices from direct
contact with water. Replace any device
exposed to water. (Does not apply to
Supply Air Sensors, Return Air Sensors,
Suction Line Sensors, Liquid Line Sensors.)
CONTRACTOR SUPPORT:
1-877-424-1715
0037-7660002

Advertisement

loading

Summary of Contents for Emerson Sensi Predict kit

  • Page 1 CONTRACTOR SUPPORT: 1-877-424-1715 INDOOR KIT INSTALLATION & ACTIVATION GUIDE The Sensi™ Predict kit is designed for conventional, residential HVAC equipment (furnace, AC, & heat pumps) in homes that have Internet access. The Sensi Predict system acts as a monitor only and does not provide any HVAC control.
  • Page 2 SENSI PREDICT INSTALL KIT INCLUDES: ™ INDOOR KIT Transformer Harness 120VAC Sensi Predict Data Hub Current Sensor Power Transformer Transformer Harness 120VAC/240VAC – 24VAC 240VAC CABLE & SENSORS Supply Air Sensor Return Air Sensor Black Wire Gray Wire Suction Line Sensor Liquid Line Sensor Main Cable Yellow Wire...
  • Page 3 1. SETUP GATEWAY* CONFIRM WI-FI AND NOTE EQUIPMENT DATA *Gateway is an optional accessory–if not used jump to step 3 1. POWER THE SENSI PREDICT CONFIGURED GATEWAY •  Connect the Gateway power adapter to an outlet near the existing home router. • ...
  • Page 4 3. INSTALL OPTIONAL OUTDOOR SENSOR KIT (instructions included with kit) 4. PAIRING 1. WPS PAIRING (all steps must be completed within 2 minutes) •  Press the WPS button located on the gateway or have the homeowner start the WPS push-button pairing process for their wireless network (if supported otherwise go to step 2.) • ...