Addr.
Name
(Hex)
Alarm Event
00DFh
Count
00E0h
Reserved
– 00FF

3.1 Analog Output 1 (0x0000)

A read returns a value of the LEL output current in microamps.

3.2 Operating Mode (0x0001)

This read/write accessible register reports the current operating mode for the Ultima OPIR-5
Detector. A Read command returns the present Ultima OPIR-5 Detector mode, represented by the
enabled bit. The following table shows the mode represented by each bit in the 16-bit register.
Table 9: Bitmap for Operating Mode Register (Read-Only Access)
Bit Position
7
Mode
Not
Used
Description
Hex Value
0x0080
Decimal Value
128
Bit Position
15
Mode
Not
Used
Description
Hex Value
0x8000
Decimal Value
32768
A Read command returns the present ULTIMA OPIR-5 mode, represented by the enabled bit.
Descriptions of the modes are provided below.
Run Mode: Ultima OPIR-5 Detector normal operation mode, with LEL measurement taking
place. Writing 1 to mode register allows to abort zero/calibration/gas check, if gas concentration
is less then 5% of Full Scale
Zero Mode: Zeroing of the Ultima OPIR-5 Detector in progress. Writing 0x0004 to mode
register sends the unit to zero mode.
Startup Mode: Ultima OPIR-5 Detector is initializing during powerup.
Alignment Mode:
installation to align the receiver and transmitter. At the end of alignment mode, the mode
switches to Zero Mode to compensate for background gas levels.
Ultima OPIR-5 Modbus Programming Guide
Function
Total Alarm Event Count
N/A
6
5
Startup
Not
Not
Mode
Used
Used
0x0040
0x0020
0x0010
64
32
16
14
13
12
Not
Not
Not
Used
Used
Used
0x4000
0x2000
0x1000
16384
8192
4096
Ultima OPIR-5 Detector is in alignment mode. This is used during
15
Data
Data Range
Type
Numeric
0 - 65535
Value
N/A
N/A
4
3
2
Not
Zero
Used
Mode
0x0008
0x0004
8
4
11
10
Not
Not
Used
Used
0x0800
0x0400
2048
1024
R/W
R
N/A
1
0
Not
Run
Used
Mode
0x0002
0x0001
2
1
9
8
Gas
Align
Check
Mode
0x0200
0x0100
512
256