Model:
Aries-P1.5/C1.5
Flowchart: Replacing, Adding & Switching the Fusing Unit Components
(Web Cleaning Unit/Hot Roller/Fusing Belt/Pressure Roller/Thermistor)
* The flowchart below is an example of when replacing the Web Cleaning Unit.
Open the front doors.
system from activating.)
Write down the current counter values for the items below.
Web Cleaning:Distance Counter
Web Cleaning:Pg Counter
Web Total:Page Counter
Skip this procedure if the component to be replaced is brand new
Manually input the counter values into the SP accordingly
with the fuser unit number. (See the next page.)
From the Adjustment Settings for Skilled Operators
menu, select the registered fusing unit number.
Check the counter values for the selected
fusing unit to be installed.
Check that the page counter data is reflected to
the Adjustment Settings for Skilled Operators
menu.
Install the fusing unit with replaced components
and close the front doors.
T
echnical
Start
(Leave the doors open to prevent the
Is the Web Cleaning Unit to be
replaced brand new?
No
Finish
B
ulletin
Date:
15-Jul-11
Write down, clear, or input the
following counters accordingly with
the component to be replaced.
.
Yes
Reset the Cleaning Web counter SP7622-129.
PAGE: 8/8
No.:
RM077042a
Replacing the Web Cleaning Unit
* Web Cleaning Distance Counter
* Web Cleaning Page Counter
* Web Total Page Counter
Replacing the Hot Roller
* Hot Roller Distance Counter
* Hot Roller Page Counter
Replacing the Fusing Belt
* Fusing Belt Distance Counter
* Fusing Belt Page Counter
Replacing the Pressure Roller
* Pressure Roller Distance Counter
* Pressure Roller Page Counter
Replacing the Thermistor
* Thermistor Distance Counter
* Thermistor Page Counter

Hide quick links: