Hardware Protection Points
In normal operation, the charge parameter limits are set by the Pylontech battery and communicated
through the system by the
Low Voltage: When the battery discharges to 44.5V or less, battery protection will turn on.
High Voltage: If charging voltage above 54V, battery protection will turn on.
Working discharge temperature range is from -10 to 50 degrees celsius.
Charging temperature range is from 0 to 50 degrees celsius.
Discharge Current Limit set to 0A at 47V, inverter will turn off.
Over-charge and Over-discharge Current Limit 102A for 15 seconds, 200A for 0.1 seconds and
400A short circuit current.
If operation is attempted outside the operating range, the battery will disconnect to protect itself.
6. VE.Direct MPPT Settings
In normal operation the MPPT charge characteristics are governed by the
instructions from the connected Pylontech battery.
This section presumes familiarity with
The settings below can be set as a precautionary measure.
MPPT Parameter Setting
Battery voltage.
48V
Absorption voltage 53V