Description Of Controller's Status And Faults - SAJ PDS33 Series User Manual

Solar pump controller
Hide thumbs Also See for PDS33 Series:
Table of Contents

Advertisement

PDS33 Series

6.3 Description of controller's status and faults

Description
Controller's
status
Controller's
fault
Communication
address
3000H
8000H
Command content
0001:FWD running
0002:REV running
0003:Stand-by
0004:Fault
0005:Under voltage
0006:Exchanging between
0000:No error
0001:Reserved
0002 :Over current during
acceleration
0003 :Over current during
deceleration
0004 : Over current at
constant speed
0005:Over voltage during
acceleration
0006:Over voltage during
deceleration
0007 : Over voltage
constant speed
0008 : Overload of buffer
resistor
0009:Under voltage error
000A:Controller overload
000B:Motor overload
000C:Input phase loss
000D:Output phase loss
000E:Module overheat
000F:External error
0010 : Communication
abnormal
0011:Relay failure
- 48 -
Attributes of
read or write
R
at
R

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents