Panasonic SL-PC104 Instruction Manual page 10

Sensor & wire-saving link system s-link pc/104 bus s-link control board

Advertisement

 +0/    1XPEHU RI 6/,1. XQLWV ZKHUH (5 KDV RFFXUUHG
It indicates the number of S-LINK units where ER4 has occurred.
ER4 can be released ("0") by switching on again either the S-LINK system side power supply
9 '& RU WKH 3& EXV SRZHU VXSSO\ FRPSXWHU SRZHU VXSSO\ DIWHU IDXOW UHFWL¿FDWLRQ
 +0/    1XPEHU RI FRQQHFWHG 6/,1. XQLWV
It indicates the number of connected S-LINK units.
 +0/   $ 6\VWHP DGGUHVV OHQJWK
It indicates the S-LINK system address length set by the system address length setting switches
(SA0 and SA1) of "3) Mode switch" of "3. Functional Description."
One of the numerical values 32, 64, 96 or 128 is indicated.
 +0/   % $GGUHVV RI 6/%6$ ZKHUH RSHUDWLRQ VWRSV
 +0/   & $GGUHVV RI FRQQHFWHG 6/%6$
Booster SL-BS1A's connection and operation conditions are indicated.
SL-BS1A
address
0
1
2
3
4
5
6
Note: Not valid if booster SL-BS1A is not used.
9
Connection address
bit
Assignment
0
1
2
ON (= 1): Connected
3
OFF(= 0):
Not connected
4
5
6
Operation stop address
bit
Assignment
0
1
2
ON (= 1):
3
Stop, abnormal
OFF (= 0): Operating
4
5
6