Download Print this page

Power Supply - Panasonic SL-PC104 Instruction Manual

Sensor & wire-saving link system s-link pc/104 bus s-link control board

Advertisement

1. Introduction
Thank you very much for using Panasonic products. Please read this Instruction Manual carefully
and thoroughly for the correct and optimum use of this product. Kindly keep this manual in a con-
venient place for quick reference.
Never use this product in a device for personnel protection.
In case of using devices for personnel protection, use products which meet laws and standards, such
as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
Before touching this product, remove any electrostatic charge that may be present on your body.
There is a danger of this product getting damaged due to the electrostatic charge.
2. Cautions

Power supply

Verify that the supply voltage variation is within the rating. Also, check the voltage variation at
the end terminal of the transmission route, since voltage drop occurs depending on the diam-
eter or the length of the transmission cable.
If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.)
terminal of the power supply is connected to an actual ground.
Do not use during the initial transient time (approx. 0.5sec.) after the power supply is switched
ON.
Make sure to use an isolation transformer for the DC power supply. If an auto-transformer (sin-
gle winding transformer) is used, this product or the power supply may get damaged.
In case a surge is generated in the power supply used, connect a surge absorber to the supply
and absorb the surge.
Wiring
Do not run the wires together with high-voltage lines or power lines or put them in the same
raceway. This can cause malfunction due to induction.
Make sure to carry out the installation and wiring in the power supply OFF condition.
In order to reduce noise, make the wiring as short as possible.
$OZD\V XVH WKH VSHFL¿HG WUDQVPLVVLRQ FDEOH
Take care that wrong wiring will damage the product.
Environment
This product has been developed / produced for industrial use only.
In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the
vicinity of this product, connect the frame ground (F.G.) terminal of the equipment to an actual
ground.
Do not use the product in places where there is excessive vapor, dust or corrosive gas, or in a
situation where the product could be exposed directly to water or chemicals.
Do not use the product in places where the ambient temperature or the humidity exceeds the
VSHFL¿FDWLRQV
Others
Please refer to "S-LINK Design Manual" for details of the system design.
Any protective devices or safety circuits against system malfunction should be designed to be
external to the system.
1

Advertisement

loading