Malfunction causes and remedies
Defect
The device will
not switch on
The device is
not providing
heat.
In the display
appears
the indicator
In the display
appears
the indicator
46
In this section you will receive important information for malfunction localization
and remedies.
WARNING
Observe the following safety information to avoid danger and property damage:
Repairs to electronic devices may only be carried out by specialists who
have been trained by the manufacturer. Considerable danger to the con-
sumer and damage to the device can occur as a result of incorrect repairs.
The following table will help with localizing and remedying minor malfunctions:
Possible cause
The mains plug is not inserted.
The mains power socket is not
providing power
The main switch POWER
not switched on.
POWER/MODE
or
has not been activated.
12
The heating element is defective.
The heating element
sively overheated
Malfunction of the integrated
temperature sensor
NOTICE
If you cannot solve the problem with the aforementioned methods please
contact customer service.
Solution
Insert the plug into the mains power
socket.
Check the house fuses
is
6
Switch on the main switch POWER
Activate the POWER/MODE
3
button and/
and/or
Get in touch with customer service.
Switch off the device at the main
switch POWER
is exces-
9
mains plug.
Allow the device to cool for a few
minutes.
Switch the device off and on at the
main switch POWER
If the indicator continues to appear
get in touch with the customer service
department.