Transmitter Section - Kenwood TS-590SG Service Manual

Hf / 50mhz transceiver
Hide thumbs Also See for TS-590SG:
Table of Contents

Advertisement

TS-590SG

Transmitter Section

Item
Condition
• Perform the following in the adjustment mode. Item 2~24.
To terminate the adjustment menu in the middle, save your settings with Menu No. 72.
1. Final idling
1) Display f.: 14.100MHz
current
Mode : USB
Final unit (A/2)
VR1, 2, 3, 4: MIN
Transmit
2. ALC refer-
1) Menu No.: 23 (14.1MHz, USB)
ence volt-
Transmit
age
3. HF Max
1) Menu No.: 24 (14.1MHz, CW)
power
Transmit
(100W)
4. 14.1MHz
1) Menu No.: 24 (14.1MHz, CW)
Null
Transmit
5. Power meter
1) Menu No.: 25 (14.1MHz, CW)
100W
Transmit
6. 50M Max
1) Menu No.: 26 (50.1MHz, CW)
power
Transmit
(100W)
7. 50M Power
1) Menu No.: 27 (50.1MHz, CW)
meter 100W
Transmit
8. POC 50W
1) Menu No.: 28 (14.1MHz, CW)
Transmit
9. Power meter
1) Menu No.: 29 (14.1MHz, CW)
50W
Transmit
10. POC 25W
1) Menu No.: 30 (14.1MHz, CW)
Transmit
11. Power
1) Menu No.: 31 (14.1MHz, CW)
meter 25W
Transmit
94
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Ammeter
Final
DC IN
Final
(A/2)
(A/2)
DC V.M
TX-RX
TP1
Front
(A/2)
(ALC)
panel
Power meter
Rear
ANT 1
150W ATT
panel
Power meter
Rear
ANT 1
Final
150W ATT
panel
(A/2)
DC V.M
Final
TP2
(A/2)
(VSR)
Power meter
Rear
ANT 1
Front
150W ATT
panel
panel
Adjustment
Parts
Method
Check the default
current (I
) of DC IN.
2
VR1
I
+ 650mA = I
±50mA
2
A
VR2
I
+ 1000mA = I
±100mA
A
B
VR3
I
+ 1000mA = I
±50mA
B
C
VR4
I
+ 1000mA = I
±50mA
C
D
[
]
Set the adjustment
2.5V±0.1V
or [
value within the limit
]
of the specifi ed volt-
age.
Set the adjustment
100W±3.0W
value within the
limit of the specifi ed
power.
TC1
VSR voltage min.
0.3V or less
[
]
1 push
Power meter lights up to
100W position.
[
]
Set the adjustment
100W±3.0W
or [
value within the
]
limit of the specifi ed
power.
[
]
1 push
Power meter lights up to
100W position.
[
]
Set the adjustment
50W±2.0W
or [
value within the
]
limit of the specifi ed
power.
[
]
1 push
Power meter lights up to 50W
position.
[
]
Set the adjustment
25W±1.0W
or [
value within the
]
limit of the specifi ed
power.
[
]
1 push
Power meter lights up to 25W
position.
Specifi cations / Remarks

Hide quick links:

Advertisement

Table of Contents
loading