Kenwood TS-590SG Service Manual page 90

Hf / 50mhz transceiver
Hide thumbs Also See for TS-590SG:
Table of Contents

Advertisement

TS-590SG
Item
Condition
4. MCF
1) Display f.: 29.200MHz
(73.095MHz)
Mode: FM
Spectrum analyzer setting
Center f.: 73.095MHz
Frequency span: 100kHz
XdB/DIV: 10dB
TG level: 0dBm
RBW: 3kHz
VBW: 10kHz
Connect the tracking genera-
tor output to CN303.
Connect the spectrum ana-
lyzer input to CN304.
5. RX Trap
1) Display f.: 21.4MHz
Mode :USB
• 11.3745MHz
PRE-AMP: ON
SSG f.: 11.3745MHz
SSG output: –30dBm (7.07mV)
• 44.150MHz 2) Display f.: 21.4MHz
Mode: USB
PRE-AMP: ON
SSG f.: 44.150MHz
SSG output: –30dBm (7.07mV)
6. FM discrimi-
1) Display f.: 29.200MHz
nator
Mode: FM
PRE-AMP: ON
AF output: 0.63V/8
SSG f.: 29.200MHz
SSG output: –53dBm
(0.501mV)
MOD: 1kHz
DEV: 3kHz
7. 1st mixer
1) Adjustment of VR261
balance
2) Menu No.: 06 (100kHz, USB)
PRE-AMP: OFF
SSG: OFF
90
ADJUSTMENT
Measurement
Test-
Unit
Terminal
Unit
equipment
Tracking
TX-RX
CN303
TX-RX
generator
(A/2)
CN304
(A/2)
Spectrum
analyzer
SSG
Rear
ANT 1
panel
AF V.M
EXT. SP
SSG
Oscilloscope
AF V.M
Distortion
meter
DM.SP
Audio
analyzer
SSG
Rear
ANT 1
panel
AF V.M
EXT. SP
Adjustment
Parts
Method
L326
Adjust the coils to
L374
obtain the frequency
L375
response as shown.
L376
L253
Check S-meter is
If S-meter is appear, turn SSG
L255
not appear.
level settings down until S-
AF output min.
meter is not appear.
Repeat adjust for 2
to 3 times.
TC105 Check S-meter is
not appear.
AF output min.
AF max.
L595
Adjust the L595 to
AF maximum output
of 0.63V/ 8 ohms.
Check the distortion
2.3% or less
and the waveform is
a good sine wave.
VR261 Adjust the volume
position of VR261 as
shown.
VR321 Noise min.
Specifi cations / Remarks
73.095MHz
3dB
3dB
7.5
7.5
kHz
kHz