Kenwood TS-590SG Service Manual page 25

Hf / 50mhz transceiver
Hide thumbs Also See for TS-590SG:
Table of Contents

Advertisement

Ref. No.
Use / Function
Power supply control of RX circuit
Q921,922 Switching
(ON during reception)
Power supply control of FM circuit
Q924
Switching
(ON when TX FM mode is selected)
RX power supply control
Q925
Switching
(ON during transmission)
TX IF amplifi er (73.095MHz)
Q952
Amplifi er
Gain is controlled according to
the ALC voltage
D11,12
Clipper
External modulation input
Reverse current
D13
External standby
prevention
D14
Surge protection
ACC2 connector (5-pin SQC)
D15
Surge protection
ACC2 connector (9-pin PKS)
Reverse current
D17
Linear amplifi er control signal
prevention
D18
Surge absorption
Relay (K11)
Reverse current
D19
Linear amplifi er control signal
prevention
Reverse current
D20~23
Paddle/key control line
prevention
D24
Surge protection
ACC2 connector (2-pin RTTY)
Reverse current
D25
Linear amplifi er control signal
prevention
D101
Surge absorption
External RX antenna terminal
D102
Surge absorption
Relay (K101)
D103
Surge absorption
Relay (K102)
D104~107 Surge absorption
Internal circuit protection
RX/TX changeover, ON during
D108
Switching
reception
ON when receiving over
D109,110 Switching
1.705MHz is selected
D111
Surge protection
Receiver RF signal input
ON when BPF of 522kHz~
D131
Switching
1.705MHz is selected
ON when BPF of 13.9~14.5MHz
D132
Switching
is selected
ON when BPF of 49~54MHz is
D133
Switching
selected (TX only)
ON when BPF of 6.9~7.5MHz is
D134
Switching
selected
ON when BPF of 30~522kHz is
D135
Switching
selected
ON when BPF of 1.705~2.5MHz
D136
Switching
is selected
ON when BPF of 2.5~4.1MHz is
D137
Switching
selected
ON when BPF of 4.1~6.9MHz is
D138
Switching
selected
ON when BPF of 7.5~10.5MHz is
D139
Switching
selected
COMPONENTS DESCRIPTION
Operation / Condition / Compatibility
Ref. No.
Use / Function
D140
Switching
D141
Switching
D142
Switching
D143
Switching
D144
Switching
D145
Switching
D146
Switching
D147
Switching
D148
Switching
D149
Switching
D150
Switching
D151
Switching
D152
Switching
D153
Switching
D154
Switching
D155
Switching
D156
Switching
D200
Surge absorption
D231
Switching
D232
Switching
D233
Switching
D234
Switching
Reverse current
D235
prevention
D261,281 Switching
D301
Switching
D302
Switching
D321
Switching
D323
Switching
TS-590SG
Operation / Condition / Compatibility
ON when BPF of 10.5~13.9MHz
is selected
ON when BPF of 14.5~21.5MHz
is selected
ON when BPF of 21.5~30MHz is
selected
ON when BPF of 30~60MHz are
selected
ON when BPF of 522kHz~
1.705MHz is selected
ON when BPF of 30~522kHz is
selected
ON when BPF of 1.705~2.5MHz
is selected
ON when BPF of 2.5~4.1MHz is
selected
ON when BPF of 4.1~6.9MHz is
selected
ON when BPF of 6.9~7.5MHz is
selected
ON when BPF of 7.5~10.5MHz is
selected
ON when BPF of 10.5~13.9MHz
is selected
ON when BPF of 14.5~21.5MHz
is selected
ON when BPF of 21.5~30MHz is
selected
ON when BPF of 30~60MHz are
selected
ON when BPF of 13.9~14.5MHz
is selected
ON when BPF of 49~54MHz is
selected (TX only)
Relay (K103)
ON when receiving preamplifi er
is OFF
ON when receiving preamplifi er
is ON
ON when receiving preamplifi er
is OFF
ON when receiving preamplifi er
is ON
1/2: Receiving ON at 21.5~30MHz
2/2: Receiving ON at 30~60MHz
ON when RX 1st IF of 11.374MHz
is selected
ON when RX 1st IF of 11.374MHz
(NB1 function OFF) is selected
ON when RX 1st IF of 11.374MHz
(NB1 function ON) is selected
ON when RX 1st IF of 73.095MHz
is selected
RX/TX changeover, ON during
reception
25