12-Pin Amphenol Plug - Simrad ES120-7C Installation Manual

Split-beam transducer
Hide thumbs Also See for ES120-7C:
Table of Contents

Advertisement

12-pin Amphenol plug

The transducer socket on the transceiver allows you to connect one or more single or split
beam transducers using a 12-pin Amphenol plug (97-24-19P).
In order to connect the transducer cable to the plug, the plug must be disassembled as
described below.
A
Disassemble the plug.
Remove a few
B
millimeters of the
insulation on the
individual cables.
Fold the outer and inner
C
screen backwards, and
fasten them temporary
with tape.
D
Thread each
wire through a
heat-shrinkable tubing,
solder the wire end
to the appropriate pin,
and insulate with the
heat-shrinkable tubing.
E
Remove the tape from
the outer and inner
screen, and spread the
screens out to place
them between the large
washers.
Assemble the plug
F
house, and tighten the
rubber sleeve.
Related topics
Splicing the transducer
cable, page 39
Installing the transducer cable, page 30
Connecting the transducer cable to the transceiver, page 42
ES120-7C Connecting to a 12-pin Amphenol socket, page 46
Splicing the cable using a grounded junction box, page 40
Splicing the cable using a junction box isolated from vessel's ground, page 40
330254/B
Cable layout and interconnections
49