FLEX LINER
FLEX
COUPLING
Flex Liners to the Appliance Connector using
four sheet metal screws each. (Figure 9) In
either case, make sure the Flex Liners do not
sag behind the appliance. Finally, move the
appliance into its appropriate place.

GENERAL MAINTENANCE

Conduct an inspection of the venting system
semiannually. Recommended areas to inspect are
as follows:
1. Check areas of the Venting System which are
exposed to the elements for corrosion. These
will appear as rust spots or streaks, and in
extreme cases, holes. These components should
immediately be replaced.
2. Remove the cap and remove any bird nests, or
other foreign material.
3. Check for evidences of excessive condensate,
such as water droplets forming in the liners, and
subsequently dripping out at joints. Continuous
condensate can cause corrosion of caps, liners, and
fittings. It may be caused by having exterior portions
of the system being exposed to cold weather.
CO-LINEAR CONNECTORS
SHEET METAL
SCREWS
Figure 6
FLEX LINERS
SHEET METAL SCREWS
SHEET METAL SCREWS
STANDARD TERMINATION CAP
CO-AXIAL TO CO-LINEAR
CONNECTOR
Figure 9
CO-LINEAR TO
CO-AXIAL ADAPTER
FLEX LINERS
BASEPLATE
Figure 7
HIGH WIND
TERMINATION CAP
Figure 8
FLEX LINERS
SHEET METAL SCREWS