13. Use a licensed electrician to wire the Da-Lift.
See Figure 14 (120 volt) or Figure 15 (220 volt).
Plug the power supply into the receptacle of the
Da-Lift.
14. Wire the wall switch supplied with the Da-Lift.
See Figure 16.
15. A control panel may be connected to the Da-Lift
by using the wall switch wire leads. The control
panel must provide a momentary, dry contact
closure of at least 1/2 second.
a. Use 3-conductor 20-24 AWG wire to
connect the control panel to the wall
switch leads. See Figure 16.
b. A momentary closure across the white
and red wires will be an "up" command.
c. A momentary closure across the white
and black wires will be a "down"
command.
d. A momentary closure across the white,
red, and black wires will be a "stop"
command.
CAUTION: Never apply voltage to the wall switch
leads or the Da-Lift will be damaged.
16. Optional Infrared (IR) or Radio Frequency (RF)
remote controls are available. To install either
remote, remove the Covers from the Control Box.
Route the Receiver Cable through the Da-Lift and
plastic bushing of the Control Box. Plug the
Receiver Cable into the motor control board port
labeled "EYE". See Figure 17. Plug IR or RF
receiver into other end of Receiver Cable. "Learn"
the RF remote and receiver by following the
directions supplied with the RF.
120V AC
Figure 14
60 Hz
SUPPLY
COMMON
GROUND
RECOMMENDED WIRE SIZE: 12 AWG
220V AC
50 Hz
Figure 15
SUPPLY
COMMON
GROUND
RECOMMENDED WIRE SIZE: 12 AWG
Figure 16
RECOMMENDED WIRE SIZE: 20-24 AWG
Figure 17
HOT
BLACK (HOT)
WHITE (COMMON)
GREEN (GROUND)
HOT
BROWN (HOT)
BLUE (COMMON)
GREEN (GROUND)
WHITE WIRE
BLACK WIRE
RED WIRE
UP
STOP
DOWN
RED WIRES
BLACK WIRES
WHITE WIRES

Advertisement