Specifications and features
Current Draw: 60mA
l
Voltage: Draws current from the PowerSeries Neo or PowerSeries Pro alarm controller
l
(10.8VDC to 12.5VDC) - (Limited Power Supply)
Frequency: 433MHz (HSM2HOST4), 868MHz (HSM2HOST8), 912-919MHz
l
(HSM2HOST9
Zones - can receive signals from up to 128 wireless zones, plus 16 wireless keypads. Also
l
sup-ports up to 32 wireless keys or 32 panic pendants
Supervisory - programmable supervisory window
l
Can be wired up to 1000 ft. / 230 m from the main panel with 22 AWG wire
l
Connects to Corbus
l
Compatibility: The HSM2HOST is used with PowerSeries Neo or PowerSeries Pro alarm
l
pan-els
Operating temperature: NA= 0°C – +49°C (32-122°F); EU= -10°C – +55°C
l
Relative humidity: 93% non-condensing
l
Built-in wall and case tampers
l
Note: For Commercial BURG (UL) the Supervisory window shall be set to 4 hours.
For Residential Fire (UL/ULC) the Supervisory window shall be set to 200 seconds.
For Residential BURG (UL/ULC) the supervisory window shall be set to 24 hours.
For UL Home Healthcare applications the supervisory window shall be set to 24 hours
Only models operating in the band 912-919 MHz are UL/ULC listed where indicated. Only UL
approved devices are to be used with UL/ULC listed systems.